FCS Multi Channel System Controllers For Gas Detection
Available with Modbus® or BACnet® communication with BAS, supports 4-20 mA and Modbus® driven VFDs
High performance Controller with logic and priority settings for monitoring toxic, combustible and refrigerant gases with versatile control functionality
The FCS Flexible Control System is a sophisticated, high performance controller that offers multi-channel configurations for monitoring toxic, combustible and refrigerant gases with versatile control functionality for non-hazardous, non-explosion rated, commercial and light industrial applications. The FCS is designed to accept inputs from digital and/or analog transmitters and/or Peripheral Devices (in various combinations),using Modbus® RTU RS-485 or 4-20 mA analog input.
The FCS is available in 4 channel, 8 channel, 32 channel and 128 channel models with either Modbus® RTU RS-485 WAN output or with BACnet® MS/TP RS-485 WAN output for communicating with a Building Automation System (BAS).
All models include, four configurable SPDT dry contact relays with field configurable time delays and trigger levels, a full colour LCD resistive touch screen with LED panel indicating configurable channel alarm status, relay status and fault conditions, intuitive menu system with password protection, enhanced logic control, priorities/zoning capabilities, a USB port for firmware upgrades, data logging and a door-mounted, audible alarm. The FCS has flexible configuration settings for analog outputs and supports 4-20 mA and Modbus® driven VFDs.
Optional value added features include, analog inputs and/or analog outputs, a top mounted strobe, a locking door, a manual shut off switch and a water tight, door-mounted audible alarm.
Features
- Available in 4 channels, 8 channels, 32 channels and 128 channels
- FCS-M models offer Modbus® RTU RS-485 digital output signal for LAN and WAN communications
- FCS-B models offer BACnet® MS/TP RS-485 output signal for WAN communications (for communicating with a BAS)
- Graphic, full colour, touchpad LCD screen with LED indicators
- Intuitive menu system with password protection
- Optional internal analog inputs and/or analog outputs with flexible configuration settings
- Enhanced logic control, zoning and priority structure capabilities
- Supports 4-20 mA and Modbus® driven VFDs
- 4 dry contact relays, 5A @ 240V each
- 2 dedicated horn/strobe output drives, 0.5A @ 24VDC max
- Line Voltage (90 - 240 VAC)
- USB port for firmware upgrades and data logging
- Configurable to comply with California Title-24 Energy Efficiency Standards
- Door mounted audible alarm, optional water tight version available
- Standard water / dust tight, corrosion resistant enclosure (drip proof); IP54 rated with water tight, door mounted audible alarm installed
The FCS can be connected to the following CET remote devices:
- Remote strobe/horns
- Remote Display Module (CET-RDM)
- Remote Relay Module (RLY-4 and/or RLY-8)
- LNK-AI Analog Input device
- LNK-AO Analog Output device
- LNK-XT Network Extender
- Remote Power Supply (RPS-24VDC)
Model
FCS-M
High performance controller with up to 128 channel configurations, comes with Modbus LAN communication, Modbus WAN output, 4 internal 5A @240 VAC SPDT relays, 2 strobe / horn alarm outputs, standard door mounted buzzer, graphic 8.1 cm (3.2 in) LCD resistive touch screen display and data logging
Mechanical
Enclosure | ABS / Polycarbonate, copper coated interior to reduce RF interference IP54 rating with door mounted, water tight buzzer installed |
Weight | 1.8 kg / 4 lbs |
Size | 254 x 226 x 113 mm / 10.0 x 8.9 x 4.44 in |
User Interface
Display | 8.1 cm (3.2”) graphic, 1/4 VGA full colour resistive touch LCD screen with LED indicators for “POWER”, “STATUS 1, 2 and 3” and “FAULT” |
Input/Output
Input | Modbus® RTU RS-485 input 4-20 mA analog input (optional) |
Output | Modbus® RTU RS-485 output to networked devices Modbus® RTU RS-485 output to BAS or DDC (FCS-M models) BACnet MS/TP RS-485 output to BAS or DDC (FCS-B models) 2 outputs drives for strobe/horn, 0.5 A @ 24 VDC max Field configurable 4-20 mA or 0-10 volts analog output (optional) |
Relays | 4 internal SPDT dry contact relays, 5 A @ 240 VAC |
Audible Alarm | Standard loud, door mounted buzzer, 90 dB @ 30 cm (1 ft) Optional: door mounted, water tight buzzer, 85 dB @ 60.96 cm (2 ft) |
Top Mounted Strobe | Optional: bright, red, top mounted strobe, 10 - 30 VDC, 13 cm H x 6.1 cm dia / 5.2 inches H x 2.4 inches dia |
Electrical
Power Requirement | Line Voltage: 90 – 240 VAC, 50 -60 Hz, 75 W |
Current Draw | Line Voltage (110 VAC): approx. 1.0 amps Line Voltage (220 VAC): approx. 0.5 amps |
Power Distribution | Total power available for Remote & Peripheral Devices and Options 65 W @ 24 VDC |
Wiring | Line Voltage: VAC 3-conductor shielded minimum 18 AWG stranded within conduit LAN Modbus® RTU (version 1.1b3) RS-485, 16 gauge, 4-conductor shielded WAN (output to BAS only): Modbus® RS-485 or BACnet® MS/TP, 4-conductor shielded |
Fuses | Thermal, resetting |
Environmental
Operating Temperature | -20°C to 40°C (-4°F to 104°F) |
with internal heater | -40°C to -40°C (-40°F to 104°F) |
Operating Humidity | 15 - 90% RH non-condensing |
Certifications
Conforms to: | CSA-C22.2 No. 205-12, UL508 (Edition 17):2007 EMC Directive 2004/108/EC, EN 50270:2006, Type 1, EN61010 FCC. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCS-B, FCS-B-X models are Listed by BTL (where X represents one or more factory installed Options) RoHS compliant circuit boards |
Can we help you?