Environment
New
    FCS Multi Channel System Controllers For Gas DetectionFCS Multi Channel System Controllers For Gas DetectionFCS Multi Channel System Controllers For Gas Detection
CRFCSM-000

FCS Multi Channel System Controllers For Gas Detection

Available with Modbus® or BACnet® communication with BAS, supports 4-20 mA and Modbus® driven VFDs


View QuoteBuy now

Fast response from our specialists

Why buy from Geneq? - find out more


High performance Controller with logic and priority settings for monitoring toxic, combustible and refrigerant gases with versatile control functionality

The FCS Flexible Control System is a sophisticated, high performance controller that offers multi-channel configurations for monitoring toxic, combustible and refrigerant gases with versatile control functionality for non-hazardous, non-explosion rated, commercial and light industrial applications. The FCS is designed to accept inputs from digital and/or analog transmitters and/or Peripheral Devices (in various combinations),using Modbus® RTU RS-485 or 4-20 mA analog input.

The FCS is available in 4 channel, 8 channel, 32 channel and 128 channel models with either Modbus® RTU RS-485 WAN output or with BACnet® MS/TP RS-485 WAN output for communicating with a Building Automation System (BAS).

All models include, four configurable SPDT dry contact relays with field configurable time delays and trigger levels, a full colour LCD resistive touch screen with LED panel indicating configurable channel alarm status, relay status and fault conditions, intuitive menu system with password protection, enhanced logic control, priorities/zoning capabilities, a USB port for firmware upgrades, data logging and a door-mounted, audible alarm. The FCS has flexible configuration settings for analog outputs and supports 4-20 mA and Modbus® driven VFDs.

Optional value added features include, analog inputs and/or analog outputs, a top mounted strobe, a locking door, a manual shut off switch and a water tight, door-mounted audible alarm.

Features

  • Available in 4 channels, 8 channels, 32 channels and 128 channels
  • FCS-M models offer Modbus® RTU RS-485 digital output signal for LAN and WAN communications
  • FCS-B models offer BACnet® MS/TP RS-485 output signal for WAN communications (for communicating with a BAS)
  • Graphic, full colour, touchpad LCD screen with LED indicators
  • Intuitive menu system with password protection
  • Optional internal analog inputs and/or analog outputs with flexible configuration settings
  • Enhanced logic control, zoning and priority structure capabilities
  • Supports 4-20 mA and Modbus® driven VFDs
  • 4 dry contact relays, 5A @ 240V each
  • 2 dedicated horn/strobe output drives, 0.5A @ 24VDC max
  • Line Voltage (90 - 240 VAC)
  • USB port for firmware upgrades and data logging
  • Configurable to comply with California Title-24 Energy Efficiency Standards
  • Door mounted audible alarm, optional water tight version available
  • Standard water / dust tight, corrosion resistant enclosure (drip proof); IP54 rated with water tight, door mounted audible alarm installed

The FCS can be connected to the following CET remote devices:

  • Remote strobe/horns
  • Remote Display Module (CET-RDM)
  • Remote Relay Module (RLY-4 and/or RLY-8)
  • LNK-AI Analog Input device
  • LNK-AO Analog Output device
  • LNK-XT Network Extender
  • Remote Power Supply (RPS-24VDC)

Model

FCS-M
High performance controller with up to 128 channel configurations, comes with Modbus LAN communication, Modbus WAN output, 4 internal 5A @240 VAC SPDT relays, 2 strobe / horn alarm outputs, standard door mounted buzzer, graphic 8.1 cm (3.2 in) LCD resistive touch screen display and data logging

Mechanical

EnclosureABS / Polycarbonate, copper coated interior to reduce RF interference
IP54 rating with door mounted, water tight buzzer installed
Weight1.8 kg / 4 lbs
Size254 x 226 x 113 mm / 10.0 x 8.9 x 4.44 in
 

User Interface

Display8.1 cm (3.2”) graphic, 1/4 VGA full colour resistive touch LCD screen with LED indicators for “POWER”, “STATUS 1, 2 and 3” and “FAULT”
 

Input/Output

InputModbus® RTU RS-485 input
4-20 mA analog input (optional)
OutputModbus® RTU RS-485 output to networked devices
Modbus® RTU RS-485 output to BAS or DDC (FCS-M models)
BACnet MS/TP RS-485 output to BAS or DDC (FCS-B models)
2 outputs drives for strobe/horn, 0.5 A @ 24 VDC max
Field configurable 4-20 mA or 0-10 volts analog output (optional)
Relays4 internal SPDT dry contact relays, 5 A @ 240 VAC
Audible AlarmStandard loud, door mounted buzzer, 90 dB @ 30 cm (1 ft)
Optional: door mounted, water tight buzzer, 85 dB @ 60.96 cm (2 ft)
Top Mounted StrobeOptional: bright, red, top mounted strobe, 10 - 30 VDC, 13 cm H x 6.1 cm dia / 5.2 inches H x 2.4 inches dia
 

Electrical

Power RequirementLine Voltage: 90 – 240 VAC, 50 -60 Hz, 75 W
Current DrawLine Voltage (110 VAC): approx. 1.0 amps
Line Voltage (220 VAC): approx. 0.5 amps
Power DistributionTotal power available for Remote & Peripheral Devices and Options 65 W @ 24 VDC
WiringLine Voltage: VAC 3-conductor shielded minimum 18 AWG stranded within conduit
LAN Modbus® RTU (version 1.1b3) RS-485, 16 gauge, 4-conductor shielded
WAN (output to BAS only): Modbus® RS-485 or BACnet® MS/TP, 4-conductor shielded
FusesThermal, resetting
 

Environmental

Operating Temperature-20°C to 40°C (-4°F to 104°F)
with internal heater-40°C to -40°C (-40°F to 104°F)
Operating Humidity15 - 90% RH non-condensing
 

Certifications

Conforms to:CSA-C22.2 No. 205-12, UL508 (Edition 17):2007
EMC Directive 2004/108/EC, EN 50270:2006, Type 1, EN61010
FCC. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
FCS-B, FCS-B-X models are Listed by BTL (where X represents one or more factory installed Options)
RoHS compliant circuit boards