• Combustion Analyzer

Combustion Analyzer


View Quote

Can we help you?

The testo 330-2G LL combustion analyzer offers combustion analysis in colorful charts and graphics. For faster and easier troubleshooting with the 330-2G LL you set the parameters and watch real time results on the display in either standard “line” view or graphic view during tuning adjustments.

The 330-2G LL provides easy operation with simple icons and intuitive menus. Bluetooth optional, a 4-year warranty -- the longest in the market -- and long life O and CO Sensors, with an expected sensor life of up to 6 years, makes the 330-2G LL a combustion analyzer that will serve you well.

 

Features

  • Measures O , CO, (NOx option), draft & temperature (ambient & flue)
  • Calculates CO , efficiency, excess air, CO air free
  • Long-Life sensors (up to 6 years) with over-range protection
  • On-board instrument diagnostics & quick leak check
  • User defined fuels
  • USB interface EasyHeat software for data readout,
    data logging and print via PC (option)
  • Up to 10 hrs cont. operation with lithium rechargeable batteries
  • Field replaceable pre-calibrated sensors
  • Extended CO range: 30,000ppm with over-range protection

 

Caracteristics

 

Specifications

Parameter Measuring range Accuracy : ± 1 digit Resolution Range Temp. t 90
Temperature -40 ... +1200 °C ± 0.5 °C (0 ... +100.0 °C)
± 0.5 % v.m. (remaining range)
± 0.1 °C (-40 ... +999.9 °C)
1 °C (> +1000 °C)
 
Range drawing -9.99 ... +40 hPa ± 0.02 hPa ou ± 5% v.m. (-0.50 ... +0.60 hPa)
± 0.03 hPa (+0.61 ... +3.00 hPa)
±1.5% v.m. (+3.01 ... +40.00 hPa)
(The highest value applies)
0.01 hPa  
Pressure Mes. 0 ... +300 hPa ± 0.5 hPa (0.0 ... 50.0 hPa)
± 1% v.m. (50.1 ... 100.0 hPa)
± 1.5 % v.m. (étendue restante)
0.1 hPa  
Mes. O 2 0 ... 21 %Vol. ±0.2 %Vol. 0.1 %Vol. ˂ 20 sec
Mes. CO (without
compensation H 2 )
0 ... 4.000 ppm ± 20 ppm (0 ... 400 ppm)
± 5% v.m. (401 ... 2.000 ppm)
± 10% v.m. (2001 ... 4.000 ppm)
1 ppm ˂ 60 sec
Mes. CO
(compensed H 2 )
0 ... 8000 ppm ± 10 ppm ou ± 10% v.m. (0 ... 200 ppm)
± 20 ppm ou ± 5% v.m. (201 ... 2.000 ppm)
± 10% v.m. (2001 ... 8000 ppm)
1 ppm ˂ 40 sec
Automatic Dilution on testo 330-2 LL
Mes. CO
(compensed H 2 )
0 ... 30.000 ppm ±100 ppm (0 ... 1.000 ppm)
±10% v.m. (1001 ... 30.000 ppm)
1 ppm  
Definition
degree efficiency
 (Eta)
0 ... 120%   0.1%  
Losses Fumes 0 ... 99.9%   0.1 %  
Determination
du CO 2
Digital Calculation based on O 2
0 ... CO 2 max ±0.2 %Vol. 0.1 %Vol. ˂ 40 sec
Option – Mes.
CO low
0 ... 500 ppm ± 2 ppm (0 ... 39 ppm)
± 5% v.m. (40 ... 500 ppm) ± 10% v.m. (2.001 ... 3.000
0.1 ppm ˂ 30 sec
Option – Mes. NO 0 ... 3.000 ppm ± 5 ppm (0 ... 100 ppm)
± 5% v.m. (101 ... 2.000 ppm)
± 10% v.m. (2.001 ... 3.000 ppm)
1 ppm ˂ 30 sec
Ambiant Mesureament of CO
 (with
probe CO)
0 ... 500 ppm ± 5 ppm (0 ... 100 ppm)
± 5% v.m. (101 ... 2.000 ppm)
ppm)
1 ppm ˂ 35 sec
Mesuring Leaks gas to the gas flammable  (with detection probe gas Leak) 0 ... 10.000 ppm
CH 4 / C 3 H 8
Signal
Affichage optique (LED)
Signal acoustique par vibreur
  Vibreur
˂ 2 sec
Mesureament of CO 2
ambiant (with probe CO 2
ambiant)
0 ... 1 %Vol.
0 ... 10 000 ppm
± 50 ppm ou ± 2% v.m. (0 ... 5.000 ppm)
± 100 ppm ou ± 3% v.m. (5001 ... 10000 ppm)
   
NO low 0 ... 300 ppm ± 2 ppm (0 ... 39.9 ppm)
± 5% v.m. (40 ... 300 ppm)
0.1 ppm ˂ 30 sec
Pressure differential, flow and temperature means of the probe fine pressure ± 10.000 Pa
0.15 ... 3 m/s
max. -40 ... +1.200 °C
(in terms of probe)
± 0.3 Pa (0 … 9.99 Pa) + ± 1 digit
± 3% v.m. (10 … 10.000 Pa)
± 0.5 °C (-40 … 100 °C)
± 0.5 % v.m. (remaining range)
+ Accuracy of the probe
0.1 m/s
0.1 °C
 

 

General Specifications

Temp. of storage -20 ... +50 °C
Temp. of service -5 ... +45 °C
Power supply Li Ion rechargeable, AC 6.3V/1.2A
Mémory 500,000 Readings
Display Color Graphic (240x320 pixels)
Weight 1.5 lbs