Materials Testing
    Concrete accelerated carbonation test chamberConcrete accelerated carbonation test chamberConcrete accelerated carbonation test chamber

Concrete accelerated carbonation test chamber

  • FDM - CB-CS series

Standard EN 12390-12

High-tech laboratory instruments that test the reaction of different product specimens to specific environmental conditions, like temperature and humidity.

View Quote

Fast response from our specialists

Why buy from Geneq? - find out more


Concrete accelerated carbonation test chamber

The CB-CS series is the standard FDM climate chamber category: you can select different temperature, humidity and volume parameters.

You can also choose between a cyclic or a constant climatic chamber: the cyclic climate chamber was developed for programming different test cycles with different temperatures during the same test.

The climatic chamber is an extremely important laboratory tool also and above all because the various tests to be carried out are regulated by different standards, established by official research bodies.

Advantages

  • Volumes from 140 up to 2300 liters
  • Adjustable temperature 0°C...+70°C*
  • Humidity range 10...98%
  • Internal shelves adjustable in height
  • Programmable controller revoFACE or stillFACE for stable testing
  • Internal forced and homogeneous ventilation
  • High and low temperature and humidity alarms

The stillFACE controller
is designed for stability testing.

The revoFACE programmer
is designed for cycle testing.

Positive Range (S)C140SC370SC440SC700SC900SC1200SC1500SC2300S
Temperature range without humidity [°C]0...+70
Temperature performance
Temperature uniformity depending on setpoint [± K]0.5..2.5
Temperature fluctuation depending on setpoint [± K]0.1..0.5
Average heating-up rate according to EN 60068-3-5 [K/min]+2
Average cooling down rate according to EN 60068-3-5 [K/min]-1-0.6-1-0.6-1
Performance Data Climate
Temperature range [°C]
humidity is on
+10/+70
Humidity range in according to Chart [% r.h.]10/98
Humidity fluctuation depending on setpoint [± %]≤ 3
Humidification systemUltrasonic humidifcation system
Water filterWater softening filter and replaceable cartridge equipped*
Max Water hardness permitted600 ppm CaCO3
Water inletPressure 0.2-5 BAR
Temperature 10-40°C
Pipe connection 3/4”
Outer dimensions
Width net [mm]5306006007501200150015002250
Depth [mm]810786868980868860980980
Height [mm]9501920192021001920210021002100
Doors
Unit doors11112223
Internal Dimensions
Width [mm]4505005006001090134013002090
Depth [mm]540480580670580570670670
Height [mm]520.51257125713401257135013401340
Measures
Interior net volume [L]130310370530810102011801830
Net weight of the unit (empty) [kg]7898108165195210213365
Permitted load per rack [kg]3030303030303030
Fixtures
Number of shelves (std./max.)3/53/53/53/66/106/126/129/14
Shelf Width [mm]400460460530460530530530
Shelf Depth [mm]500470570650570550650650
stillFACE Controller
ControllerConstant monitoring temperature and humidity controllers
Interface portOptional: RS485
revoFACE Programmer
Set-up DIsplayProgramme status, set up temperature and humidity, date, time and language
Programmer10 programs and 50 segments each, adjustable from 1 min. to 999 hrs.
CalibrationPossibility to calibrate all parameters
Interface portOptional: RS485 - Optional: Ethernet - Wifi - Dedicated mobile app
Environment-specific data
Sound-pressure level [dB(A)]60
Structure and insulation
Exterior materialStainless steel AISI 304
Internal materialStainless steel AISI 304
InsulationCFC and HCFC free
Shelf grillRemovable and height adjustable stainless steel plastic coated
Ventilation
Fanforced ventilation
Safety
TemperatureClass 2 independent adjustable temperature safety devices (DIN 12880)
AlarmAudio-Visual
Electrical data
Rated Voltage [V]220/240
Power frequency [Hz]50
Nominal power [kW]     (S)1.41.51.41.82.22.42.62.7
Nominal power [kW]     (B)1.61.71.72.32.62.72.93.1
Unit fuse [A]16
Phase (nominal voltage)1 ~
 

* The cartridge should be change every 4-6 months at most.

All technical data are specified for units with standard equipment at an ambient temperature of +24 °C and a voltage fluctuation of ±10 %.