New
BMD Testing Accessories
- Controls - 82-P0375 ...
AASHTO T393 / TP124 , ASTM D8044, ASTM D8225, ASTM D8360, EN 12697-44
The BMD Testing Accessories for performing Balanced Mix Design tests with Automatic Multipurpose Testers.
Compatible for use with the BalancedLoader testing system.
Specifications
Semi-Circular Bend (SCB) to EN 12697-44
Test set to perform the SCB test in the digital mode, including:
- 82-P0375 Load cell 50 kN capacity
- 82-P0375/C Adapter to fit load cell (two pieces)
- 82-P0322 Displacement transducer, 25 mm travel
- 34-T0104/81 Adjustable transducer holder
- 34-T0104/13 Compression device extension
- 34-T0104/10 Compression device
- 79-PV70119 Indirect Tensile Jig Guided Platen Assembly (100mm& 150mm diameter)
- 79-PV70130 Semi-Circular Bend Test Jig for EN12697-44
Semi-Circular Bend (SCB) to ASTM 8044, AASHTO T393/TP124 Method B
Test set to perform the SCB test, including:
- 82-P0375 Load cell 50 kN capacity
- 82-P0375/C Adapter to fit load cell (two pieces)
- 82-P0322 Displacement transducer, 25 mm travel
- 34-T0104/81 Adjustable transducer holder
- 34-T0103/1 Adjustable CBR penetration piston
- 34-T0104/13 Compression device extension
- 34-T0104/10 Compression device
- 79-PV70150 Indirect Tensile (IDT) and Semi-Circular Bend (SCB) Jig Base
- 79-PV70155 Semi-Circular Bend (SCB) Top Platen
- 79-PV70156 Semi-Circular Bend (SCB) Jig Upgrade Kit Option for ASTM D8044 / AASHTO
- T393/TP124 Method B
Semi-Circular Bend (SCB) to AASHTO T393/TP124 Method A
Test set to perform the SCB test, including:
- 82-P0375 Load cell 50 kN capacity
- 82-P0375/C Adapter to fit load cell (two pieces)
- 82-P0322 Displacement transducer, 25 mm travel
- 34-T0104/81 Adjustable transducer holder
- 34-T0103/1 Adjustable CBR penetration piston
- 34-T0104/13 Compression device extension
- 34-T0104/10 Compression device
- 79-PV70150 Indirect Tensile (IDT) and Semi-Circular Bend (SCB) Jig Base
- 79-PV70155 Semi-Circular Bend (SCB) Top Platen
- 79-PV70157 Semi-Circular Bend (SCB) Jig Upgrade Kit Option for AASHTO T393/TP124 Method A
IDEAL-CT (Cracking Tolerance Index) to ASTM D8225
- 82-P0375 Load cell 50 kN capacity
- 82-P0375/C Adapter to fit load cell (two pieces)
- 82-P0322 Displacement transducer, 25 mm travel
- 34-T0104/81 Adjustable transducer holder
- 34-T0104/13 Compression device extension (two pieces)
- 34-T0104/10 Compression device
- 76-B0078/F Frame for tensile splitting device
- 76-B0078/F2 Pair of loading strips for 150 mm dia. sample
IDEAL-RT (Rutting Tolerance Index) to ASTM D8360
- 82-P0375 Load cell 50 kN capacity
- 82-P0375/C Adapter to fit load cell (two pieces)
- 82-P0322 Displacement transducer, 25 mm travel
- 34-T0104/81 Adjustable transducer holder
- 34-T0104/13 Compression device extension (two pieces)
- 34-T0104/10 Compression device
- 76-B0078/F Frame for tensile splitting device
- 76-B0078/RT Accessory for IDEAL-RT test. To be mounted onto 76-B0078/F base
Do you have a question?