Débitmètre à turbine en ligne
- Badger Meter - QuikSert
Voir la soumission
Réponse rapide par nos spécialistes
Avantages de faire affaire avec Geneq - en savoir plus
The Gas QuikSert turbine flow meter provides long service life by offering a durable construction design composed of stainless steel and tungsten carbide shaft and bearings.
The unique wafer style design allows for quick installation and easily fits between two flanges. Gas QuikSert is fully compatible with all Blancett flow monitors, K-factor scalers, and intelligent converters. The Gas QuikSert is compatible with most instruments, PLCs and computers.
Features and Benefits
- Consistent, reliable gas flow measurement.
- Wafer mounting configuration for limited space requirements.
- Light weight, balanced rotor provides instantaneous response to changes in flow.
- No mating flange design allows for quick and easy install.
- Superior material of construction for high performance in aggressive environments.
Mechanical Dimensions inches(mm)
Flow Meter | Repair Kit |
Hardware Kit | |
Part Number Construction | ||||||||
Flow Meter* | Flow Rate | K-Factor | Repair Kit*** | Hardware Kit | ||||
ACFM** | MCFD | Pulses/ft³ (Pulses/m³) | ||||||
B142-20L | 7 - 70 | 10 - 100 | 365 (12,900) | B142-20L-KIT | B142-20-150KIT | |||
B142-20M | 14 - 210 | 20 - 300 | 190 (6,710) | B142-20M-KIT | ||||
B142-20H | 35 - 350 | 50 - 500 | 85 (3,000) | B142-20H-KIT |
* Does not include magnetic pickup. Order Blancett B111113 Low Drag Pickup
** At 0 PSIG (0 Bar) and 60 ºF (15.6 ºC)
*** Compatible with Cameron/NuFlo 2" wafer gas meter
Installation | Mounts between two 2" ANSI raised face flanges, ideally sized for 2-inch schedule 40 or 80 pipe; horizontal or vertical orientation |
Working Pressure | Vacuum to 2,220 PSIG (15.3 MPa) maximum |
Pressure Loss | 3 inches of water column (7.5 mbar) maximum (dry air) |
Temperature | -40 to +330 ºF (-40 to +165 ºC) |
Linearity | ±2% of reading over the specified measuring range (see Part Number Construction table below) |
System Uncertainty | ±1% of reading when integrated with a properly configured Blancett flow monitor or signal conditioner |
Repeatability | ±0.5% of reading |
Output Signal | 100 mVpp minimum (with Blancett B111113 magnetic pickup installed) |
Nominal K-Factor | See Part Number Construction table below |
Materials of Construction | 316/316L, 410 and 304 grade stainless steels, tungsten carbide |
Certifications | Intrinsically Safe: Class I Division 1 Groups C, D [Entity Parameters Vmax = 10V, Imax = 3 mA, Ci = 0 μF and Li = 1.65 H with Blancett B111113 magnetic pickup installed] for US and Canada. Complies with UL 913 and CSA 22.2 No. 157-92 Explosion-Proof: Class I Division 1 Groups C, D. Complies with UL1203 and CSA C22.2 No. 30-M1986 Single Seal: complies with ANSI/ISA 12.27.01-2003 |