Environment
 
    Détecteur de la qualité de l’air intérieur - IAQ

Détecteur de la qualité de l’air intérieur - IAQ


Voir la soumission

Réponse rapide par nos spécialistes

Avantages de faire affaire avec Geneq - en savoir plus


Simultaneously measures multiple parameters such as: CO, CO2, Temperature, RH, to monitor IAQ.

  • Calculates Dew Point, Web Bulb Temperature, Absolute Humidity, Humidity Ratio and % Outside Air
  • Simplifies the labor involved and eliminates the need to purchase and learn multiple instruments
  • Easy user self-calibration
  • Checks CO2 levels and determine the rate of exchange, or the % of outside air, being introduced to a building per ASHRAE standard 62
  • Examines building IAQ conditions to optimize worker productivity
  • NIST Traceable Calibration Certificate*
  • Features quick start-up and high accuracy in measuring CO2 and CO concentration levels in the environment
  • Sampling function records multiple point measurements

*NIST TRACEABLE CALIBRATIONS available


Applications

  • IAQ Investigation
  • Building Commissioning
  • Thermal Comfort Control
  • Employee Health
  • Industrial Hygiene
Measurement Specifications
CORange0 to 500PPM
Accuracy+/-3% of reading or +/-3PPM whichever is greater
Resolution0.1PPM: 0-99PPM 1PPM: 100-500 PPM
CO2Range0 to 5000PPM
Accuracy+/-3% of reading or+/-50PPM whichever is greater
Resolution1PPM
TemperatureRange– 4 to 140F (-20 to 60C)
Accuracy+/- 1F (+/-0.5C)
Resolution0.1F (0.1C )
Relative HumidityRange2 to 98%RH
Accuracy2 to 80%RH:±2%RH, 80 to 98%RH:±3%RH
Resolution0.1%RH
General Specifications
FunctionNormal ModeNormal measuring (do not store and calculate the data.) Relative humidity, CO, CO2, Dew point, Wet bulb temperature, Absolute humidity and Humidity Ratio
Calculation ModeStore the data, and calculate the maximum, minimum and average value.
% OA ModeMeasure ventilation ratio (Ask for ventilation ratio by calculating from temperature and CO2 value)
Data Output ModePerform re-calculation of stored data and output of data to PC and Printer.
Calibration ModePerform the calibration of CO and CO2.
OutputDigitalRS232C
Analog (option)DC 0 to 1V
Power Supply AAA Battery x 4 (Mn, Alkaline, or Ni-Cd)
Analog (option)DC 0 to 1V
DimensionsUnit3.5″ x 7.5″ x 2.0″
ProbeLength: 12.5 inch / Diameter: 1.0 inch
Weight 1.2 lbs (500g))
What’s included Meter, Operation manual, AA batteries, Probe stand,Probe,
Calibration cap, Connection tube, Data processing software(DPS),RS-232C
cable, Carrying case, NIST TRACEABLE CALIBRATION certificate