Record accurate and reliable pH, mV, ORP, dissolved oxygen and temperature measurements with the Thermo Scientific Orion Star A216 pH, DO and RDO Benchtop Meter.

Ideal for a wide range of applications and advanced pH and dissolved oxygen analysis in the lab. Use the two channels to measure pH and dissolved oxygen simultaneously or view each channel separately. Use an RDO optical or polarographic DO probe for ultimate flexibility in sensors. Log up to 2000 data point sets with time / date stamp and easily transfer calibration and data logs via USB or RS232 to a printer or computer.

Thermo Scientific Orion Star A216 pH/RDO/DO benchtop meters are easy to use, dependable laboratory meters with advanced features and functions. Selectable read modes and stability indicator give you flexibility and control over your testing. All critical data is shown with your measurements including temperature, date and time, read type, measurement stability, active calibration information and electrode condition icon. Onscreen calibration and setup instructions can be displayed in several local languages with new languages added through software updates. 

Navigation is fast and simple due to the comprehensive keypad with menu-specific function keys, dual purpose scroll/shortcut keys, plus power, measure, log view and stirrer keys that ensure easy operation. All setup menus are in one location with direct access using a single shortcut key so you can quickly access, evaluate and change measurement and instrument settings.

  • Combined convenience with the benefits of a pH meter and dissolved oxygen meter in one easy-to-use system
  • Measure pH, mV, relative mV or ORP with temperature on channel one and measure dissolved oxygen in percent saturation or mg/L with temperature using RDO optical DO probes or polarographic DO probes on channel two
  • Easily view individual measurements on a full screen display and quickly toggle to a split screen display to view multiple measurements simultaneously
  • Perform up to a five point pH calibration using automatic buffer recognition of NIST or DIN buffer groups with choice to manually enter custom buffer values and calibration editing option that allows individual points to be fixed without a full recalibration
  • Calibrate dissolved oxygen using water-saturated air, air-saturated water, custom value (Winkler titration) and zero point options
  • Automatically compensate dissolved oxygen readings using ATC temperature, manual salinity input and built-in barometer for barometric pressure readings
  • Informative, easy-to-read backlit graphic display with clear onscreen instructions simplifies operation
  • Capture your critical readings with measurement stability indicator and selectable read modes – Auto-Read holds a stable reading, Continuous shows changing readings with hold option and Timed logs data at specific intervals
  • Eliminate the need for magnetic stir bars using the meter-controlled stirrer probe (catalog number 096019) to uniformly mix solutions
  • Data log collects and date/time stamps up to 2000 measurement sets with optional sample ID and user ID
  • Calibration log stores ten most recent calibrations
  • Non-volatile meter memory ensures your data and settings are protected, even with loss of power
  • Orion Star Com software facilitates data transfer to a computer via USB or RS232 connections
  • Flexible power options with universal power adapter or optional AA batteries
  • IP54-rated housing resists dust and splashes and can be wall-mounted if table space is limited
  • Meters include CE, TUV 3-in-1 and FCC Class A certifications and 3-year replacement warranty

Many configurations, electrodes, consumables and accessories available on request.

Range (pH) -2.000 to 20.000pH
Resolution (pH) 0.1, 0.01, 0.001pH
Accuracy (pH) ±0.002pH
Range (mV) ±2000.0mV
Range (Relative mV) ±2000.0mV
Range (ORP) ±2000.0mV
Resolution (mV) 0.1mV
Accuracy (mV) ±0.2 mV or ±0.05% of reading whichever is greater
Isopotential Point 7.000pH
Range (Polarographic DO) 0.00 to 90.00mg/L
Resolution (Polarographic DO) 0.01, 0.1mg/L
Accuracy (Polarographic DO) ±0.2mg/L or ±2% of reading, whichever is greater
Range (RDO) 0.00 to 50.00mg/L
Resolution (RDO) 0.01, 0.1mg/L
Accuracy (RDO) ±0.1mg/L up to 8mg/L, ±0.2mg/L from 8 to 20mg/L, ±10% of reading up to 50mg/L
Percent Saturation Range (Polarographic DO) 0.0 to 600.0 % saturation
Percent Saturation Resolution (Polarographic DO) 0.1, 1 % saturation
Percent Saturation Relative Accuracy (Polarographic DO) ±2 % saturation or ±2% of reading whichever is greater
Percent Saturation Range (RDO) 0.0 to 500.0 % saturation
Percent Saturation Resolution (RDO) 0.1, 1 % saturation
Percent Saturation Relative Accuracy (RDO) ±2 % saturation ≤ 200 % saturation, ±10 % saturation > 200 % saturation
Barometric Pressure Correction 400 to 850mmHg, automatic using built-in barometer or manual entry
Pressure Range 400 to 850mmHg
Pressure Resolution 1mmHg
Accuracy (Barometer) ±6mmHg
Salinity Factor 0.0 to 45.0 ppt, automatic correction using manual entry of sample salinity
Calibration pH with calibration editing option, relative mV (RmV), ORP, dissolved oxygen and temperature
Calibration Points (pH) 1 to 5
Calibration Points 1 point relative mV (RmV) mode, 1 point ORP mode
Calibration Modes Water-saturated air, air-saturated water, manual (Winkler titration), zero point
Range (Temperature) -5.0° to 105.0° C, 22.0° to 221.0° F
Resolution (Temperature) 0.1°C, 0.1°F
Accuracy (Temperature) ±0.1°C
Temperature Selection Manual or automatic with ATC temperature probe
Temperature Probe Calibration 1 point temperature offset calibration
Channels 2
Display Type Graphic LCD with backlight
Backlight Option Yes, selectable
Keypad Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys
Measurement Modes pH, mV, relative mV (RmV) or ORP with temperature; dissolved oxygen as % saturation or mg/L with temperature and barometric pressure
Stability Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting
Data Management Details Transfer single, range or all data points to printer or computer
Data Points 2000 with date and time stamp
Log Function Type Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous measure mode
Memory Non-volatile memory preserves data log, calibration log and meter settings
Alarm Output High/low limit alarm, calibration due alarm
Methods 10 per channel with password protection
Languages English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update
Inputs BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), 9 pin MiniDIN (RDO optical or polarographic DO sensor with built-in temperature), stirrer input (stirrer probe)
Outputs USB, RS232
Power Supply Universal AC adapter (included) or 4 AA batteries (sold separately)
AC Adapter Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. 1010003)
Battery Type Four AA (sold separately)
Battery Life 800 hours
IP Rating IP-54
Certifications/Compliance CE, TUV 3-1, FCC Class A
Operating Temperature 41° to 113°F (ambient)
5° to 45° C (ambient)
Relative Humidity Range 5 to 85 %, non-condensing
Dimensions (L x W x H) 24cm x 18cm x 11cm (9.5 in. x 7.1 in. x 4.3 in.)
Weight 2 lb.
0.9kg
Warranty 3 year meter warranty