Thermosel for Viscometers
- Brookfield - Thermosel
- Compatible with standard Brookfield Viscometers and DV3T Rheometers
- For Elevated Temperature Testing
- Applications: Hot Melts, Asphalt, Wax, Polymers
Thermosel for Elevated Temperature Testing
Compatible with standard Brookfield Viscometers and DV3T Rheometers Note: requires optional cable DVP-141
Provides control
of sample temperature up to +300°C
EZ-Lock Option
Thermosel is now available with special EZ-Lock spindle coupling for use on standard Brookfield Viscometers/Rheometers already equipped with the EZ-Lock feature
Temperature Ramping
between set points is possible if used with RheocalcT (DV3T & DV2T) Software Note: Requires optional cable HT-106
Thermo Container
Heating Chamber
Computer Controlled
when used with DV2T or DV3T and RheocalcT Software (HT-106 cable required)
Programmable Temperature Controller
offers single set point or up to 10 programmable set points.
Direct Temperature Control Possible
with DV2T/DV3T Rheometer
What’s Included?
- Choice of one SC4 Spindle Specify when ordering
- Alignment Bracket
- Thermo Container with safety guard and insulating cap
- 1 Removable Sample Chamber
- 5 Disposable Sample Chambers Order additional chambers in quantities of 100, HT-2DB-100
- 18” Lab Stand Rod
- Extracting Tools
- Temperature Controller with an RTD probe
Applications
- Hot Melts
- Asphalt
- Wax
- Polymers
The difficulty with viscosity measurements of hot melts and liquids at elevated temperatures has been in maintaining accurate temperature control that is consistent from sample to sample so that meaningful data could be obtained. The Brookfield Thermosel solves this problem by providing a stable, precisely controlled sample environment. This, together with the inherent accuracy of the Brookfield Viscometers, is fundamental to the Thermosel System, which produces viscosity measurements that are not only accurate but entirely reproducible.
Several factors contribute to the stable environment:
Non-fluctuating temperature control Small sample volume and insulated sample chamber which reduces temperature gradients within the sample The rotating spindle, which acts as a built-in stirring device The test procedure is quite straightforward. Once familiar with the system, unskilled operators can easily produce accurate, reproducible data.
Thermosel Viscosity Ranges cP(mPa•s) | ||||||||
SPINDLE | SC4-18 | SC4-31 | SC4-34 | SC4-21 SC4-27* SC4-28 SC4-29 | HT-DIN-81** | |||
SAMPLE VOLUME | 8mL | 10mL | 9.5mL | 8mL 10.5mL 11.5mL 13mL | 7mL | |||
SHEAR RATE (sec-1)† MODEL | 1.32N | .34N | .28N | .93N .34N .28N .25N | 1.29N | |||
DV3TLV | 1.2-30K | 12-300K | 24-600K | Not applicable for historical reasons. However, it is possible to use the above spindles with any of these instruments. Digital Viscometers/Rheometers will automatically calculate viscosity. if you require information on viscosity range. | 1.0-10K | |||
DV2TLV | 1.5-30K | 15-300K | 30-600K | 3.4-10K | ||||
LVDV-IP | 3-10K | 30-100K | 60-200K | 3.4-10K | ||||
LVDVE | 3-10K | 30-100K | 60-200K | N/A | ||||
LVT | 5-10K | 50-100K | 100-200K | 5.7-10K | ||||
DV3TRV | Not applicable for historical reasons. However, it is possible to use the above spindles with any of these instruments. Digital Viscometers/Rheometers will automatically calculate viscosity. | 20-500K | 100-2.5M | 200-5M | 400-10M | 14.6-10K | ||
DV2TRV | 25-500K | 125-2.5M | 250-5M | 500-10M | 36.5-10K | |||
RVDV-IP | 50-170K | 250-830K | 500-1.7M | 1K-3.3M | 36.5-10K | |||
RVDVE | 50-170K | 250-830K | 500-1.7M | 1K-3.3M | N/A | |||
RVT | 50-100K | 250-500K | 500-1M | 1K-2M | 36.5-10K | |||
DV3THA | 40-1M | 200-5M | 400-10M | 800-20M | 29.2-10K | |||
DV2THA | 50-1M | 250-5M | 500-10M | 1K-20M | 73.0-10K | |||
HADV-IP | 100-300K | 500-1.7M | 1K-3.3M | 2K-6.7M | 73.0-10K | |||
HADVE | 100-300K | 500-1.7M | 1K-3.3M | 2K-6.7M | N/A | |||
HAT | 100-200K | 500-1M | 1K-2M | 2K-4M | 73.0-10K | |||
DV3THB | 160-4M | 800-20M | 1.6K-40M | 3.2K-80M | 116.8-10K | |||
DV2THB | 200-4M | 1K-20M | 2K-40M | 4K-80M | 292.0-10K | |||
HBDV-IP | 400-1.3M | 2K-6.7M | 4K-13.3M | 8K-26.7M | 292.0-10K | |||
HBDVE | 400-1.3M | 2K-6.7M | 4K-13.3M | 8K-26.7M | N/A | |||
HBT | 400-800K | 2K-4M | 4K-8M | 8K-16M | 292.0-10K |
Can we help you?
min 10 ch