Materials Testing
 
    DC Holiday Detector
EL2663-000

DC Holiday Detector

Porosity

ANSI/AWWA C213, AS 3894.1, ASTM C 536, ASTM C 537, ASTM D 4787,…

  • Voltage calculator automatically sets the correct voltage from your coating thickness value
  • Adjustable Voltage:
  • 0.5kV - 1kV in 50V steps

View QuoteBuy now

Fast response from our specialists

Why buy from Geneq? - find out more


The Elcometer 266 revolutionises high voltage DC testing of coatings porosity detection making it safer, easier and more reliable than ever before. 

The Elcometer 266 holiday detector can be used to test porosity on coatings up to 7 mm (275 mils) thick and is ideal for inspecting coatings on pipelines and other protective coatings. This holiday tester features a built-in voltage calculator which will determine and set the correct test voltage based upon the test standard and the thickness of coating being tested.


Interchangeable DC probe handlesIntegrated voltage calculator
Part NumberDescriptionEnter the test standard & the coating
thickness then the gauge will automatically programme the correct voltage
T266200331 DC5 (0,5 - 5kV)
T266200332 DC15 (0,5 - 15kV)Second hand grip is available
T266200333 DC30 (0,5 - 30kV)Ideal for testing pipes and tank floors with 2 hands - without compromising safety
T266200334 DC30S (0,5 - 30kV)Part Number
T26620081
Description
Second Hand Grip
Testing has never been saferUniversal probe adaptors
Ribbing provides additional user
protection - specifically designed to
meet EN 61010
Enables the Elcometer 266 to work with all major holiday detector’s accessories.
Removeable, quick charge batteries
Fully charge the battery pack in 4 hours,
within the gauge or separately, for up to
40 hours of continuous testing 


Features: 

  • Voltage calculator automatically sets the correct voltage from your coating thickness value
  • Adjustable Voltage:
  • 0.5kV - 1kV in 50V steps
  • 1kV to 30kV in 100V steps
  • Dual safety switch on handle to avoid accidental switch on (Grey/orange probe handles only)
  • Internal Voltmeter/ Jeep tester ensures that the test voltage equals the selected voltage
  • Visual and audible alarms, Bright LEDs on the handle, as well as a loud buzzer, clearly indicate when a holiday is detected
  • To change maximum voltage range, select a different handle; 5kV, 15kV or 30kV DC or 30kV DC continuous
  • A wide range of probe brushes and rolling springs available


Norms :

ANSI/AWWA C213, AS 3894.1, ASTM C 536, ASTM C 537, ASTM D 4787, ASTM D 5162-B, ASTM G 62-B, BS1344-11, DIN 55670, EN 14430, ISO 2746, ISO 29601, JIS K 6766, NACE RP0274, NACE RP0188, NACE RP0190, NACE RP0490, NACE SP0188, NACE SP0490.

 

 

Elcometer 266D266----4
Précision de la sortie en haute tension
±5% ou ±50V sous 1 000 Volts 
Température de fonctionnement
0°C à 50°C (32°F à 120°F)
Alimentation électrique
Batterie rechargeable, complètement chargée en 4 heures
Précision du courant mesuré
±5% de l’échelle; Courant en sortie: 0 - 100µA maximum
Autonomie - rétroéclairage éteint (allumé)
DC5: 40 (20) heures DC15: 20 (15) hours DC30: 10 (8) hours
Dimensions de la valise de transport
Valise plastique ABS; 520 x 370 x 125mm (20,5 x 14,5 x 5”)
Poids
Unité de base (batterie comprise): 1,2kg (2,7lb) Poignée: 0,6kg (1,3lb)
Liste de colisage
Porosimètre haute tension Elcometer 266 DC, pack batterie, câble spiralé pour poignée haute tension, câble de mise à la terre 10m (32’),chargeur de batterie avec prise UK, EUR, US et AUS, sonde pinceau, bandoulière, valise de transport en plastique réistant et mode d’emploi