Pull-Off Adhesion Tester
- Elcometer - 506
ASTM D4541, ASTM D7234, AS/NZS 1580.408.5, BS 1881-207,DIN 1048-2…
- Suitable for adhesion testing on metal, wood, concrete and other substrates
- Rugged & lightweight - ideal for frequent testing
- Smooth load application up to 50 MPa (7250 psi)
The Elcometer 506 are lightweight, portable, and easy-to-use adhesion testers available in analog or digital gagues and are suitable for measuring the pull-off adhesion of coatings up to 50MPa (7250psi) either on-site or in the laboratory.
Norms:
ASTM D4541, ASTM D7234, AS/NZS 1580.408.5, BS 1881-207,DIN 1048-2, EN 12636, EN 13144, EN 1542,EN 24624,ISO 16276-1, ISO 4624, JIS K 5600-5-7, NF T30-606,NF T30-062
Features:
Powerful
- Suitable for adhesion testing on metal, wood, concrete, and other substrates
- Rugged & lightweight - ideal for frequent testing
- Smooth load application up to 50 MPa (7250 psi)
Flexible
- Easy to use hand-held design
- Ideal for adhesion tests in the laboratory and the field
- 14.2, 20 and 50 mm (0.56, 0.76 & 1.96”) diameter reusable dollies
- Measures adhesion on small, curved, and flat surfaces
Accurate
- Measurement range up to 50 MPa (7250 psi) with an accuracy of ±1% of the full scale
Durable
- Sealed, heavy-duty and impact resistant
- Dust and waterproof equivalent to IP65
- Suitable for use in harsh environments
Testing coatings adhesion on concrete & low bond strength substrates
When testing coatings adhesion on low bond strength substrates such as concrete, wood, or other fibrous materials, a larger surface area of dolly is required to improve accuracy, repeatability and reproducibility.
The Elcometer 506 Concrete Adhesion Tester can be supplied as a kit or with individual 50mm accessory items (skirt, dolly, cutter) which can be added to existing Elcometer 506 gauges.
How to Prevent Adhesive and Cohesive Failures |
Preparing the surface and dolly |
|
Fixing the dolly |
|
Assessment of the Adhesion Test |
For a valid pull test, the coating must cover at least 50% of the area of the dolly face. If the glue fails and no coating is present on the dolly, or it covers less than 50% of the dolly face area, the pull-test is invalid and should be repeated. When the coating has failed within the layer leaving the same coating on both the dolly and the test panel it is known as a "cohesive failure". "Adhesive failures" occur when either the coating has failed at the interface with another coating (leaving a coating on the dolly and another coating on the substrate),or when the coating has failed at the substrate (leaving the coating on the dolly and the substrate is bare). |
NOTE: If the glue fails at a value above the specification then it can be reported that the adhesion exceeded the specification for this individual test. |
::::::::::::::::::::::: More on Elcometer products, their reliability and popularity: www.testcoatings.ca :::::::::::::::::::::::
Part Number | Description | ||
F506-20A | Elcometer 506 Analogue Adhesion Tester Kit; 20mm | ||
F506-20AC | Elcometer 506 Analogue Adhesion Tester Kit; 20mm - Certified | ||
F506-20D | Elcometer 506 Digital Adhesion Tester Kit; 20mm | ||
F506-20DC | Elcometer 506 Digital Adhesion Tester Kit; 20mm - Certified | ||
F506-50A | Elcometer 506 Analogue Adhesion Tester Kit; 50mm | ||
F506-50AC | Elcometer 506 Analogue Adhesion Tester Kit; 50mm - Certified | ||
F506-50D | Elcometer 506 Digital Adhesion Tester Kit; 50mm | ||
F506-50DC | Elcometer 506 Digital Adhesion Tester Kit; 50mm - Certified | ||
Accuracy | ±1% of full scale | ||
Pressure Rating | 26 MPa (3800 psi) | ||
14.2mm (0.56”) Dolly | 20mm (0.76”) Dolly | 50mm (1.96”) Dolly | |
Operating Range | 4 to 50 MPa (600 to 7200 psi) | 2 to 25 MPa (300 to 3600 psi) | 0.3 to 4 MPa (50 to 580 psi) |
Scale Resolution | Analogue: 0.2 MPa (20 psi) | Analogue: 0.1 MPa (10 psi) | Analogue: 0.05 MPa (5 psi) |
Digital: 0.01 MPa (1 psi) | Digital: 0.01 MPa (1 psi) | Digital:0.1 MPa (1 psi) | |
Instrument Length | 290mm (11.5”) | 290mm (11.5”) | 290mm (11.5”) |
Actuator Height (skirt fitted) | 85mm (3.4”) | 85mm (3.4”) | 110mm (4.3”) |
Instrument Weight | 1.8kg (4lb) | 1.8kg (4lb) | 2.0kg (4.4lb) |
Kit Weight | 4kg (8.8lb) | 4kg (8.8lb) | 5.2kg (11.5lb) |
Battery Type | 2 x LR6 (AA) alkaline dry batteries (digital gauge only) Battery Life: 2000 hours | ||
Packing List: | |||
20mm Kit | Elcometer 506 Adhesion Tester with 20mm dollies (x10),standard skirt for 20mm dollies, 20mm dolly cutter handle, 20mm dolly cutter, Araldite standard two part epoxy adhesive (2 x 15ml tubes),abrasive pad, carry case, 2 x LR6 (AA) batteries (Digital Gauge only),test certificate and operating instructions. | ||
50mm Kit | Elcometer 506 Adhesion Tester with 50mm dollies (x6),standard skirt for 50mm dollies, 50mm dolly cutter arbor, 50mm dolly cutter, Araldite standard two part epoxy adhesive (2 x 15ml tubes),abrasive pad, carry case, 2 x LR6 (AA) batteries (Digital Gauge only),test certificate and operating instructions. |
Can we help you?