Materials Testing
 
    HANDHELD COLORIMETER

Handheld colorimeter

For color difference detection


View QuoteBuy now

Fast response from our specialists

Why buy from Geneq? - find out more


Stable and reliable instrument for color difference detection
Repeatability accuracy is up to: dE*ab < 0.03

Key technology

Dual optical path design improves repeatability accuracy dE*ab≤0.03

The dual optical path design monitors light source energy fluctuations while measuring the sample signal, reducing interference during measurement, obtaining higher measurement stability and improving the instrument's measurement repeatability index to dE*ab ≤ 0.03, which guaranteed the measuring speed, accuracy and stability of the instrument. Related technologies are protected by Chinese invention patents and US invention patents.

Innovative 5 micron thick nano-integrated optics

After intensive research, using nano-integrated optical devices as light splitters, only 5 micron thick optical devices can achieve nano-level light splitting ability, once again leading the direction of industry innovation, greatly improving the technical performance of products. Relevant technologies are protected by Chinese invention patents.

Features

(1) Over 30 Measurement Indicators

  • RGB,Lab,Reflectance,LCh,Hunter Lab,CIE-Luv,XYZ,Yxy
  • Difference(ΔE*ab,ΔE*cmc,ΔE*94,ΔE*00)
  • WI(ASTM E313-00,ASTM E313-73,CIE/ISO,AATCC,Hunter,Taube Berger Stensby)
  • YI(ASTM D1925,ASTM E313-00,ASTM E313-73)
  • Blackness(My,dM),Color Fastness,Tint(ASTM E313-00)
  • Color Density CMYK(A,T,E,M),Milm, Munsell, Opacity, Color strength

(2) Evaluate whether the color is jumping light, and provide nearly 40 evaluation light sources A, B, C, D50, D55, D65 and nearly 40 evaluation light sources can be selected, covering almost all the color measurement indicators and light source types in the industry.

(3)Contains SCI measurement mode

SCI refers to specular reflections that are generally used to study the properties of a color itself without regard to the surface gloss of the sample to which it is attached.

(4)Contains UV for fluorescent color measurement

GENCR200-0 colorimeter still provide stable and objective reflectivity data for color measurement on surfaces containing fluorescent materials.

(5)Calibration base and zirconium reference with a Mohs hardness of 9 to calibrate the instrument, ensuring long-term stability

Compared to existing products, the GENCR200-0 spectrophotometer does not require frequent manual calibration when in use. Simply place it on the calibration base and the instrument will automatically calibrate the overall instrument function and accuracy according to its own state and environmental factors, ensuring that the instrument is always in a stable state and ready for use.

The white plate in the calibration base is the basis of the instrument's work. Through long-term investment and research, GENCR200-0 colorimeter has integrated zirconium material as the calibration white plate, with a Mohs hardness of 9. As the material itself has the hardness and stability comparable to diamond, the surface of the calibration white plate will not be scratched and will not change colour with changes in temperature and humidity. This is a further improvement in the stability and durability of the calibration whiteboard compared to similar foreign and domestic products that use common industrial ceramics or even plastic as calibration whiteboards, ensuring the performance of the instrument.

(6)The GENCR200-0 supports 6 measuring apertures for selection(11mm,6mm,3mm)Rotate to switch the caliber. Say goodbye to the tedious manual screw fixing method.

  • Stable type:Φ11mm,Φ6mm,Φ3mm
  • Dexterous type:▽11mm,▽6mm,▽3mm

(7)Built-in HD camera for clear observation of the measured area

GENCR200-0 spectrophotometer can obtain an image of the measured area through the camera when measuring, which can clearly locate the measured area of the sample and avoid inaccurate measurement due to wrong area.

(8)Support WeChat applet, Android, Apple, Hongmeng mobile APP

  • The GENCR200-0 colorimeter can be connected to a variety of mobile phones via a rich mobile app.
  • Users no longer have to pass on the colour values of samples and physical objects, they can easily pass on colour data via WeChat.
  • Users can find the most similar colours in multiple sets of colour cards.
  • Users can create personal colour databases and enter information on colour cards for printing, paint and textiles. The colour libraries created can be uploaded to the cloud for easy colour processing with data sharing across multiple devices.
  • Business users can create and manage their own colour card information library and colour recipes in the cloud, and share the information library and colour recipes to their own users through a unique invitation code.

(9)Use the powerful PC-based colour management system ColorExpert

GThe Windows color management system ColorExpert is included in the GENCR200-0 colorimeter package, which can be connected to the colorimeter through Bluetooth or USB cable.

ColorExpert is a full-featured colour management software with four functional modules: My Colours, Colour Check, Colour Matching System and Personal Centre.

Introduction to Appearance Structure

HANDHELD COLORIMETER

 
Measuring structure*D/8,SCI
Measurement repeatability**ΔE*ab≤ 0.03
Display0.01
Measuring apertureThere are 2 stable and agile models in total: Φ6mm,▽6mm
Color Spaces and IndicesReflectance, CIE-Lab, CIE-LCh, HunterLab, CIE Luv, XYZ, Yxy, RGB, Color difference(ΔE*ab, ΔE*cmc, ΔE*94,ΔE*00),WI(ASTM E313-00,ASTM E313-73,CIE,ISO2470/R457, AATCC, Hunter, Taube Berger Stensby),YI(ASTM D1925,ASTM E313-00, ASTM E313-73),Blackness(My,dM),Color Fastness
Source conditionA,B,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,U30,U35,DLF,NBF,TL83, TL84,ID50,ID65,LED-B1,LED-B2,LED-B3,LED-B4,LED-B5,LED-BH1,LED-RGB1,LED-V1,LED-V2
Light sourceLED
Measurement observation Visual
CalibrationManual calibration
Software supportAndriod,iOS,Windows, Wechat app
Guaranteed accuracyGuaranteed measurement
Observer2°,10°
Integrating sphere 40mm
StandardsCIE No.15,GB/T 3978,GB 2893,GB/T 18833,ISO7724-1,ASTM E1164,DIN5033 Teil7
Ways of spectralNano-integrated spectral devices
SensorSilicon photodiode array Dual 16-group
Wavelength interval10nm
Wavelength range400-700nm
Reflectance determination range0-200%
Reflectance resolution0.01%
Measurement methodSingle measurement, average measurement (2 to 99 measurements)
Measurement timeApprox. 1 second
InterfaceUSB, Bluetooth
Screen Screen Full colour screen, 2.4
Battery capacity8000 continuous measurements on a single charge, 3.7V/3000mAh
Life of light 10 years and 1 million cycles
LanguageSimplified Chinese, English
StorageInstrument :10,000 data; APP: mass storage
 

* Diffuse illumination / 8° directional reception with specular reflected light included / specular reflected light removed

**White plate calibration with 30 standard deviations measured at 5 second intervals after white plate calibration