Materials Testing
    Tramex non destructive roof scannerTramex non destructive roof scannerTramex non destructive roof scannerTramex non destructive roof scanner
DS2

Tramex non destructive roof scanner

  • Complies to ASTM D7954
  • Non-destructive impedance moisture meter
  • Three ranges of sensitivity enabling the inspection of a variety of roof membranes and insulation thicknesses

View QuoteBuy now

Fast response from our specialists

Why buy from Geneq? - find out more


 Ideal for water leak detection in roofing materials and integrity testing


The Tramex Dec Scanner is a mobile non-destructive impedance scanner designed for the instant surveying of moisture conditions in roofing and waterproofing systems per ASTM D7954.

The Dec Scanner detects and evaluates the moisture conditions within roofing systems by non-destructively measuring the electrical impedance. A low frequency electronic signal is generated, transmitted into the material under test via one of the two electrodes incorporated in the rubber electrode mat, and received by the second electrode. The strength of this signal varies in proportion to the amount of moisture in the material under test. The Dec Scanner determines the strength of the current and converts this to a comparative moisture content value. By moving the Dec Scanner across a roof surface in a regular pattern, a continuous reading is obtained, and areas that contain moisture can be readily identified.



Features

  • Complies to ASTM D7954
  • Non-destructive impedance moisture meter.
  • Three ranges of sensitivity enabling the inspection of a variety of roof membranes and insulation thicknesses.
  • Ergonomic easy-reach and easy to operate control panel.
  • Leak tracing, water leak detection, problem sourcing, and an instantaneous and clear indication of roof condition.
  • Fast readings over large roof areas in a short time frame.
  • Work in normal daylight hours.
  • Faster and more user friendly than nuclear meters.
  • Easy and safe to use with no regulatory restrictions or operating license required.
  • Dependable solid state circuitry and rugged molded body for long-term reliability.
  • Battery powered - 9 Volt PP3.


Operating procedure:

Moisture detection testing can be done at the time of installation for warranty auditing and quality control, as part of an ongoing maintenance program, or prior to re-roofing or repair of damaged roofs. The Dec Scanner is a durable but lightweight instrument that is easily transported to the roof surface. Having determined a known acceptably dry area, one of three sensitivity ranges is selected, and the Dec Scanner is ready to use. Without causing any damage to the roof surface, the Dec Scanner is moved over the tested area. The Dec Scanner gives continuous moisture condition readings, from which a moisture map of the surface can be drawn up, and leaks traced to their source.


Size:
30”W x 15¾“D x 6¼”H (762 mm x 400 mm x 158 mm)
Scanning area: 
24”W x 15.5”D (609 mm x 394mm)
Carry case: 
38”W x 20”D x 10”H (940mm x 508 mm x 270mm)
Weight:
 Dec Scanner 24.6 lbs (9.95 Kg)
Weight:
Carry Case 21.9 lbs (9.9 Kg)
Total Weight:
Dec Scanner in Carry Case 46.5 lbs (21.1 Kg)
Outer packaging carton weight:
4.4 lbs (2 Kg)
Total shipping weight:
51 lbs (23.1Kg)
Dimensional shipping weight:
66 lbs (30 Kg)
Display:
0 to 100
Comparative Max. depth of penetration:
6” (152 mm)
Power Supply:
 2 x 9 Volt PP3 Batteries (included)
Limitations:
Some EPDM, Butyl rubber roofing and other conductive roofing.


Range selection:

The Dec Scanner has an integrated and adjustable calibration ability allowing for precise comparative readings. There are 3 Ranges, and they should be selected as best suits the surface under test, for example:

Range 1- Most suitable for single-ply and thin roof coverings such as PVC, Hypalon and other smooth surfaces where insulation is wet and moisture is close to the surface.

Range 2- Most suitable for multi-ply built-up and modified systems, mineral surfaced felts, and other smooth or gravel surfaces where insulation is less wet and moisture is below the surface.

Range 3 - Most suitable for thicker roof coverings such as mastic asphalt, thick gravel and stone surfaced roofing