Pull-Off Adhesion Testers
- Elcometer - 106
AS 1580.408.5, ASTM D 4541, EN 13144, EN 24624, ISO 4624, ISO 16276-1
- Easy to operate
- Fully portable
The Elcometer 106 Adhesion Tester is easy to operate and fully portable Type II adhesion gauge which provides a numerical value for adhesion strength.
Applications for the Elcometer 106 Adhesion Test include paint or plasma spray on bridge decking, coatings on steel, aluminium, concrete etc.
- Supplied in a carry case - ideal for site tests
- Hand operated - no need for a power supply
- Includes a cutter for EN13144 and ISO 4624 tests
Adhesion Test Method
A test dolly is bonded to the coating using an adhesive. The Elcometer 106 adhesion tester houses a spring arrangement which applies a lift force to the dolly as the tension is increased.When the coating is pulled off the surface, an indicator on the scale shows the numerical value of adhesion strength expressed in terms of the force per unit area required to remove the dolly.Inspection of the dolly face is required to determine the failure mode.To increase sensitivity at low values or for uneven surfaces, a 40mm (1.52”) dolly is available. When using the 40mm (1.52”) dolly, divide the scale reading by 4.
Accessories | |
T1062895-10 | Spare Dollies 20mm (0.76”) Diameter (Pack of 10) |
T1062895- | Spare Dollies 20mm (0.76”) Diameter (Pack of 100) |
T1062914- | Large Dollies 40mm (1.52 Diameter (Pack of 5) |
T1062915- | Large Base Ring for 40mm (1.52")Dollies |
T99912906 | Araldite Epoxy Adhesive |
T99914009 | 20mm (0.76") Dolly Cutter |
Part Number | Description | Range | |||
MPa (N/mm2) | kg/cm2 | psi | Certificate | ||
F106----5 | Elcometer 106 Adhesion Tester - Scale 5 | 0 - 0.2 | 0 - 2 | 0 - 30 | ο |
F106----1 | Elcometer 106 Adhesion Tester - Scale 1 | 0 - 3.5 | 0 - 35 | 0 - 500 | ο |
F106----2 | Elcometer 106 Adhesion Tester - Scale 2 | 0 - 7.0 | 0 - 70 | 0 - 1000 | ο |
F106----3 | Elcometer 106 Adhesion Tester - Scale 3 | 0 - 15 | 0 - 150 | 0 - 2000 | ο |
F106----4 | Elcometer 106 Adhesion Tester - Scale 4 | 0 -22 | 0 - 220 | 0 - 3200 | ο |
Dimensions | Scales 1, 2, 5: 152 x 76mm (6 x 3”) Scales 3 and 4: 150mm | ||||
Dolly Diameter | 20mm (0.76”) | ||||
Dolly Area | 314mm² (0.49 sq inch) | ||||
Gross weight of Kit | Scale 1, 2 and 5: 2.8kg (6.2lb) Scale 3: 4.2kg (9.3lb) Scale 4: 4.5kg (9.9lb) | ||||
Packing List | Elcometer 106 Pull-Off Adhesion Tester, pack of 20 dollies, Araldite adhesive, base support ring, magnetic dolly clamp, dolly cutter, ratchet spanner (scale 3 & 4 only),carry case and operating instructions |
ο Optional Calibration Certificate available
STANDARDS