Tramex Roofing Inspection Kit
with bluetooth and accompanying app
- Tramex - RIK
- Hand held electrode with 7.8" (200mm) insulated pins
- 10" (260mm) narrow RH probe
- Hole punch
- Infrared Thermometer
It's a non destructive flat roof scanner kit for leak detection, tracing, moisture measuring and surveying.
The Tramex RIK allows for point-of-contact, non-destructive moisture testing in roofing waterproofing systems up to approximately 4 inches in depth with the RWS Roof & Wall Scanner.
The kit also allows for non-destructive measurement of moisture conditions in concrete decks and pin readings in wood decks and roofing materials, relative humidity readings, and ambient and dew point conditions using the Tramex CMEX5 digital moisture meter and probes.
An infrared surface thermometer gives surface temperature. The Tramex Roofing Inspection Kit comes with an extension handle in a protective heavy-duty carrying case with die-cut foam lining.
Bluetooth connectivity to the Tramex Meters App allows for visualization of Tramex CMEX5 readings and data reporting to mobile devices, to GeoTag test results, create, save and share photos, reports and charts, as well as see your CMEX5 meter screen on your phone when extending to hard to reach places.
Roof and Wall Scanner - RWS - Measuring Range:
Depth of penetration: | 4" (100mm) |
Sensitivity: | Four Ranges:> |
Roofing Mode with high and low sensitivity. | |
EIFS / Foam Roof Insulation Mode with high and low sensitivity. |
Concrete Moisture Encounter X5 - CMEX5 - Measuring Range:
Depth of penetration in concrete: | approx. ¾" (20mm) |
Moisture content for Concrete: | 0 → 6.9 % |
Comparative for Gypsum floor screed: | 0 → 12 |
CM Equiv Anhydrite/Concrete: | 0→2.7 / 0→4.3 |
Reference scale: | 0 → 100 |
Relative Humidity: | 0 → 99% |
(with optional Hygro-i2 ® probe): | Humidity accuracy: 0% → 99%RH +/- 2% @ 25°C / 77°F |
Moisture content for wood (with optional wood pin probes): | 5 → 30 % |
Infrared Thermometer IRT2
Temperature range: | -58ºF ~ 1202ºF (-50 to 650 ºC) |
Distance to Spot ratio: | D:S = 12:1 |
Display resolution: | 0.1 ºF(0.1ºC) <1000 1ºC >1000 |
Accuracy for targets: | Assumes ambient operating temperature of 73 to 77ºF (23 to 25 ºC) -58ºF ~ 68ºF (-50 ~ 20ºC) ±4.5ºF (2.5ºC) 68ºF ~572ºF (20ºC ~300ºC) ±1.0% ± 1.8ºF (1.0ºC) 572ºF ~ 1202ºF (300ºC ~650ºC) ±1.5% |
Repeatability: | -58~68ºF (-50~20ºC) : ± 2.3ºF (1.3ºC) 68~1202ºF (20~650ºC) : ±0.5% or ±0.9ºF (0.5ºC) |
Response time: | 150ms |
Spectral response: | 8~14um |
Emissivity: | Digitally adjustable from 0.10 to 1.0 |
Over range indication: | LCD will show “----” |
Polarity: | Automatic (no indication for positive polarity); Minus (-) sign for negative polarity |
Diode laser output: | <1mW,Wavelength 630~670nm, Class 2 laser product |
Operating temp.: | 32 to 122ºF ( 0 to 50ºC) |
Storage temp.: | 14 to 140ºF (–10 to 60ºC) |
Relative humidity: | 10%~90%RH operating, <80%RH storage |
Power supply: | 9V battery, NEDA 1604A or IEC 6LR61, or equivalent |
Safety: | “ CE ” Comply with EMC |
Specifications of Kit:
Size: | 19.2” x 14.9” x 5.7” (487mm x 380mm x 145mm) |
Weight: | 9.9 lbs (4.51kg) |
Power: | 2 x 9 volt PP3 Batteries, 2 x AALR6 ALKALINE (Included) |
Can we help you?