Clean Room Oven - CR
- Carbolite - CR Series
ISO 14644-1
- 250°C maximum operating temperature
- 30 to 1810 litre chamber volumes
- Fully sealed low thermal mass insulation to avoid shedding fibres
The CR Series of 250 °C clean room ovens comprises nine standard models in sizes from the 30 litre model to the 1790 litre model
The CR Series of 250 °C clean room ovens comprises nine standard models in sizes from the 30 litre model to the 1790 litre model which, once processed through a customer's standard material entry regime, are suitable for operation within an ISO 14644-1 Class 5 environment*.
All sources of particulate contamination are fully sealed. Their easily cleaned stainless steel interiors and gloss white epoxy exteriors prevent the shedding of particulate contamination.
*Federal Standard 209E Class 100 was superseded in 2001 by ISO 14644-1 Class 5.
Standard features
- 250°C maximum operating temperature
- 30 to 1810 litre chamber volumes
- Fully sealed low thermal mass insulation to avoid shedding fibres
- Fully enclosed brushless fan motor
- Carbolite Gero 301 controller, with single ramp to set-point & process timer
- Perforated stainless steel shelves
- Particle free silicone rubber door seal
- Membrane control panel with clear bright LED display
Options (specify these at time of order)
- Over-temperature protection (recommended to protect valuable contents & for unattended operation)
- A range of sophisticated digital controllers, multi-segment programmers and data loggers is available. These can be fitted with RS232, RS485 or Ethernet communications
- Access port for independent thermocouple
- Cable entry ports
- Viewing window
- Frame to enable units to be stacked one upon another
- Lockable door Door
- switch to isolate elements and fan
- Fully customised through wall (flange fitted) designs are available
- Optional floor stand
CR/30
Max temp (°C) | 250 |
Volume (litres) | 30 |
CR/70
Max temp (°C) | 250 |
Volume (litres) | 68 |
CR/130
Max temp (°C) | 250 |
Volume (litres) | 121 |
CR/180
Max temp (°C) | 250 |
Volume (litres) | 170 |
CR/220
Max temp (°C) | 250 |
Volume (litres) | 227 |
CR/330
Max temp (°C) | 250 |
Volume (litres) | 340 |
CR/450
Max temp (°C) | 250 |
Volume (litres) | 450 |
CR/840
Max temp (°C) | 250 |
Volume (litres) | 850 |
CR/1790
Max temp (°C) | 250 |
Volume (litres) | 1810 |
Please note:
- Uniformity is measured in an empty chamber with vents closed, after a stabilisation period
- Shelf loadings are based on evenly distributed weight
- Minimum operating temperature approximately ambient +30°C
- Maximum power and heat up time based on a 240V supply
- The uniform volume is smaller than the overall chamber volume
Content may be subject to modifications or corrections
Can we help you?
min 10 ch