The Thermo Scientific Locator inventory system makes cell sample retrieval quick and easy.
Locator Rack & Box System simplifies sample storage and retrieval with a unique hanging rack and gridded box design, advanced vacuum insulation, unmatched temperature uniformity, and an innovative liquid nitrogen monitor.
SystemsCompact design minimizes space requirements while maximizing storage capacity. Suited for both manual and computerized inventory record-keeping methods. Super-insulated vessels have a special, narrow-mouth design that conserves liquid nitrogen by minimizing evaporation
- Outstanding temperature uniformity: samples are stored below -180%C, even when less than 2" (5cm) of liquid nitrogen remains in the vessel
- Ultrasonic Level Monitor safeguards irreplaceable samples with minimal liquid nitrogen evaporation and conduction
- Advanced vacuum insulation minimizes liquid nitrogen evaporation and reduces operating costs
- The optional monitor provides a continuous LED readout of liquid nitrogen level; activates visual and audible alarms when the level falls below the safe range of approximately 1" (2.5cm)
- The optional alarm also alerts the operator in the event of excessive liquid nitrogen loss
- Secure locking hasp prevents unauthorized entry
Includes
Stainless-steel indexed racks that fit into corresponding locations in the vessel. Each rack has individual storage compartments that hold one Nalgene* Cryogenic Storage Box.
Requires
Nalgene Cryogenic Storage Boxes (order separately). Each box has individually numbered storage areas for use with vials sized 2.0mL and smaller.
Locator System Carts
These Thermo Scientific carts enable easy movement of Locator system vessels. With wheels. Molded to fit snugly around vessel base.
Additional Accessories
- Boxes, Nalgene, 2" for 1.0 and 1.5mL vials, 100 vials per box, case of 10 (CS509X24)
- Boxes, Nalgene, 2" for 2mL vials, 81 vials per box, case of 40 (CS509X4); case of 20 (CS509X5)
- Boxes, Nalgene, 4" for 5mL vials, 81 vials per box, each (CS509X10)
- CryoClaw* (AY509X18)
- Cups, Suction, 2 replacements for CryoClaw (AY509X19)
- Logbook (LT509X5)
- Level Monitor, 100-240V, customer-installed (CN509X1-70)
- Rack, for 5.0mL vials (does not include boxes) (HR509X19A)
- Vials, 1mL, case of 500 (AY509X32)
- Vials, Cryogenic, 1.2mL, case of 500, 1.2 ml (AY509X13)
- Vials, 1.5mL, case of 500 (AY509X33)
- Vials, Cryogenic, 2.0mL, case of 500, 2.0 ml (AY509X12)
Cat. No. | Model | Capacity | Vial Capacity | Average Daily Consumption | Static Holding Time | No. of Racks / Boxes per Rack / Boxes per System | Exterior (H x W) | Inside Dia. (Neck) | Shipping Weight |
Without Liquid Nitrogen Level Monitor | |||||||||
CY50925 | Locator Jr. | 60L | 1600 (100/box)1 | 0.85L | 70 days | 4/4/16 | 62.2 p 55.8cm (24.5 p 22") | 21.5cm (8.5") | 40.8kg (90 lb.) |
CY50935 | Locator 4 | 111L | 3600 (100/box)2 | 0.99L | 112 days | 4/9/36 | 90.2 p 55.8cm (35.5 p 22") | 21.5cm (8.5") | 52.2kg (115 lb.) |
CY50945 | Locator 8 | 111L | 1800 (25/box)3 | 0.6L | 185 days | 8/9/72 | 95.3 p 55.8cm (35.5 p 22") | 15cm (6") | 53.1kg (117 lb.) |
With Liquid Nitrogen Level Monitor | |||||||||
CY50955 | Locator Jr. | 60L | 1600 (100/box)1 | 0.85L | 70 days | 4/4/16 | 62.2 p 55.8cm (24.5 p 22") | 21.5cm (8.5") | 40.8kg (90 lb.) |
CY50965 | Locator 4 | 111L | 3600 (100/box)2 | 0.99L | 112 days | 4/9/36 | 90.2 p 55.8cm (35.5 p 22") | 21.5cm (8.5") | 52.2kg (115 lb.) |
CY50975 | Locator 8 | 111L | 1800 (25/box)3 | 0.6L | 185 days | 8/9/72 | 95.3 p 55.8cm (35.5 p 22") | 15cm (6") | 53.1kg (117 lb.) |
† 1.2/2mL Nalgene* cryogenic vials09_Static evaporation rates and holding times are based on new vessel performance, without any product load, or lid openings, and in a controlled environment. Actual working performance will vary with individual applications. Excludes supply tank evaporation. Total LN2 consumption will vary greatly depending on product loads, lid openings, fill cycles, and supply tank evaporation rate.