    Q30 Series Benchtop AnalyzerQ30 Series Benchtop Analyzer

Q30 Series Benchtop Analyzer

  • Intelligent
  • Durable
  • Easy Operation
  • 32-bit microprocessor
  • On-board data storage

View Quote

Fast response from our specialists

Why buy from Geneq? - find out more


Do you have a question?

Test O2 and/or CO2 levels in packages, processes, and more!

The Q30 series is the benchtop version of Quantek Instrument’s latest product line. The Q30 series of analyzers features a color display, menu driven setup and calibration, an optional built-in programable sample pump, and on-board data collection. Everything you need to start sampling is included. As always, all analyzers are backed by our industry leading 2-year warranty.

Use the intuitive interface to begin sampling immediately with no warm-up time. By default, the Q30 powers with a wall adapter (internationally compatible),but a 12-hour runtime battery can be added as an option. The Q30 series is used in hundreds of applications including container spot checks, food packages, bio enclosures/incubators, and many more!

Model: Q30  (O2)

Included :

  • Model Q30 Analyzer
  • Power Supply for Charging
  • 400 Foam Seal Pads (P/N 9002)
  • 10 Liquid and Particulate blocking filters (P/N 9028)
  • 10 needles (P/N 9027)
  • Spare tubing for sample probe
  • USB thumb drive for downloading saved data points

Model: Q31  (CO2)

Included :

  • Model Q31 Analyzer
  • Power Supply for Charging
  • Extra 1/16” ID and 3/32” ID tubing
  • 5 Liquid and Particulate blocking filters (P/N 9028)
  • 5 needles (P/N 9027)
  • Spare tubing for sample probe
  • USB thumb drive for downloading saved data points

Model: Q32  (O2 and CO2)

Included :

  • Model Q32 Analyzer
  • Power Supply for Charging
  • 400 Foam Seal Pads (P/N 9002)
  • 10 Liquid and Particulate blocking filters (P/N 9028)
  • 10 needles (P/N 9027)
  • Spare tubing for sample probe
  • USB thumb drive for downloading saved data points

ABOUT THE SENSORS

The electrochemical O2 sensor life is typically 4-5 years, unlike other analyzers with an electrochemical sensor that last 1-2 years. When required, replacement is easy and inexpensive. Both sensors are unaffected by high levels of background gases such as nitrogen.

The infrared CO2 sensor utilizes NDIR technology for maximum stability and has a theoretically unlimited lifespan. Its ultra-low power consumption allows for 10-14 hours of runtime for the analyzer before recharging is required. It has no moving parts, no consumables, and is housed in a compact optical cell. The sensor responds to CO2 only.

Oxygen Range0.00 to 100%
Oxygen Sensitivity 0.01%
O2 Resolution0.01%
Analog Output0-5V
Resolution0.01%
Accuracy+/- 1% of the reading or 0.1%, whichever is greater
Drift less than 0.4% per year
Oxygen Sensor TypeProprietary Electochemical
Response Time20 seconds to T95
O2 Sensor Lifetime4-5 Years
O2 Sensor BodyABS Resin
Sample ConnectionSample Probe
Sample MethodPump
Sample PumpInternal, draws ~5cc/sec
Pump Timing2-20 seconds, continuous, or cycling on/off, programmable
Minimum Sample Required15cc
Sampling AssemblyProbe with luer connection for tri-beveled needle, PTFE tubing
Oxygen Calibration ControlsDigital Keypad Adjustment
Instrument Calibration EasyCal calibration
Exhaust portVents to air
Power Supply100 to 240 VAC, internationally compatibile
Battery OperationIncluded, internal shrink wrapped NiMH battery pack
Input Voltage100-240V, 50-60Hz
Battery Life12-16 hour runtime
MeasuresO2
Form FactorBenchtop
Size11W x 3H x 8D in (279W x 76H x 203D mm)
Weight3.5 lbs (1.59 kg)
Warranty2 years, parts and labor
StandardsCE, RoHS
Included Consumables400 foam seal pads, 10 luer fit needles, 10 filters
Included DocumentationOwner’s manual, NIST traceable calibration certificate
Origin of GoodsMade in the U.S.A.
Carbon Dioxide Sensor TypeSolid-state Non-Dispersive Infrared
Accuracy - Carbon Dioxide± 1% of reading, or ± 0.1% CO2 (whichever is greater)
CO2 Minimum Detection Limit0.1% (0-50% or 0-100% range) or 0.01% (0-10% or 0-20% range)
CO2 Calibration ControlsDigital Keypad
CO2 Calibration FrequencyEvery 12 months; calibration gas recommended
Analog Output0-5V
Resolution0.01%
Accuracy± 1% of reading, or ± 0.1% CO2 (whichever is greater)
Driftless than 0.4% per year
Response Time20 seconds to T95
Sample ConnectionSample Probe
Sample MethodPump
Sample PumpInternal, draws ~5cc/sec
Pump Timing2-20 seconds, continuous, or cycling on/off, programmable
Minimum Sample Required15cc
Sampling AssemblyProbe with luer connection for tri-beveled needle, PTFE tubing
Instrument CalibrationEasyCal calibration
Exhaust portVents to air
Power Supply100 to 240 VAC, internationally compatibile
Battery OperationIncluded, internal shrink wrapped NiMH battery pack
Input Voltage100-240V, 50-60Hz
Battery Life12-16 hour runtime
MeasuresCO2
Form FactorBenchtop
Size11W x 3H x 8D in (279W x 76H x 203D mm)
Weight3.5 lbs (1.59 kg)
Warranty2 years, parts and labor
StandardsCE, RoHS
Included Consumables5 Filters, 5 needles, Extra tubing, 50cc syringe, USB thumb drive
Included DocumentationOwner’s manual, NIST traceable calibration certificate
Origin of GoodsMade in the U.S.A.
Carbon Dioxide Sensor TypeSolid-state Infrared
Accuracy - Carbon Dioxide± 1% of reading, or ± 0.1% CO2 (whichever is greater)
CO2 Minimum Detection Limit0.1% (0-50% or 0-100% range) or 0.01% (0-10% or 0-20% range)
CO2 Calibration ControlsDigital Keypad
CO2 Calibration FrequencyEvery 12 months; calibration gas recommended
Expected Lifetime (oxygen)4-5 years
Oxygen Range0.00 to 100%
Oxygen Sensitivity0.01%
O2 Resolution0.01%
Analog Output0-5V
Resolution 0.01%
Accuracy+/- 0.1% (from 0-20%),+/- 0.2% (from 20% to 50%),+/- 0.5% (from 50% to 100%)
Driftless than 0.4% per year
Oxygen Sensor TypeProprietary Electochemical
Response Time20 seconds to T95
O2 Sensor Lifetime4-5 Years
O2 Sensor BodyAnodized aluminum (CO2) and ABS Resin (O2)
Sample ConnectionSample Probe
Sample MethodPump
Sample PumpInternal, draws ~5cc/sec
Pump Timing2-20 seconds, continuous, or cycling on/off, programmable
Minimum Sample Required15cc
Sampling AssemblyProbe with male luer connection for side-port needle, PTFE tubing
Oxygen Calibration ControlsDigital Keypad Adjustment
Instrument CalibrationEasyCal calibration
Exhaust portVents to air
Power Supply100 to 240 VAC, internationally compatibile
Battery OperationIncluded, internal shrink wrapped NiMH battery pack
Input Voltage100-240V, 50-60Hz
Battery Life12-16 hour runtime
Measures O2, CO2
Form Factor Benchtop
Size11W x 3H x 8D in (279W x 76H x 203D mm)
Weight3.5 lbs (1.59 kg)
Warranty2 years, parts and labor
StandardsCE, RoHS
Included Consumables400 foam septas, 10 luer fit needles, 10 filters, spare probe tubing
Included DocumentationOwner’s manual, NIST traceable calibration certificate
Origin of GoodsMade in the U.S.A.