The Valueline high accuracy pressure transmitter provides outstanding performance in any new or existing pressure measurement application. The Valueline can be calibrated to any pressure range between 2 and 15,000 psi with outstanding Total Error Band (TEB) accuracy, and provides your choice of analog outputs (current or voltage). This versatility simplifies installation and ensures compatibility with most SCADA and PLC systems.

The Valueline pressure transmitter is assembled in the U.S. to customer specifications, including custom pressure ranges and cable lengths and has been certified by UL to NSF/ANSI 61 and 372 standards for use in drinking water and to UL/cUL IS-approved for hazardous location applications.

Additionally, models equipped with 4...20mA analog output include guaranteed lightning protection at no additional cost. This feature protects the pressure transmitter from fast-rising transients and carries a lifetime guarantee against damage from electrical surge.

Features

  • UL / cUL certified intrinsically safe for installation in hazardous locations
  • NSF/ANSI 61 and 372 certified construction for use in drinking water applications
  • 0.1% static accuracy, 0.25% Total Error Band (TEB) accuracy
  • 4...20mA models include guaranteed lightning protection at no additional cost
  • Durable 316L stainless steel construction, optional titanium
  • 2-year warranty covers defects in materials and workmanship
  • Standard outputs simplify interface to controls, data collection, and telemetry systems
  • Various electrical connections for easy integration into new and existing systems
  • IP68-rated cabled versions suitable for submersion
  • 2021 IIJA Build America, Buy America-compliant configurations available

Pressure Ranges - Relative0...2 PSI up to 0...450 PSI
Pressure Ranges - Absolute0...2 PSI up to 0...450 PSI
Pressure Ranges - Sealed0...500 PSI up to 0...15,000 PSI
Accuracy, Static at 25°CStandard: 0.1% FS
Optional: 0.05% FS
Accuracy, Total Error BandSee Datasheet for Details
Standard: 0.25% BR TEB
Optional: 0.1% BR TEB
Compensated Temperature-10…80°C
Operating TemperatureCable: -10…60°C
Connector: -30…100°C
ProtectionIP68 with Cable
IP65 with DIN43650 connector
CertificationsClass I, Division 1, Groups A, B, C, and D
Class II, Division 1, Groups E, F, and G
Class III
NSF/ANSI 61 & 372 for clean water use