Levelogger 6 Junior
Model 3001
The Levelogger 6 Junior provides an inexpensive alternative for measuring groundwater and surface water levels and temperature. The Levelogger 6 Junior combines a pressure sensor, temperature detector, a datalogger, and a 5-year battery (based on a 1-minute sampling rate) in one compact 22 mm x 160 mm (7/8" x 6.3") stainless steel housing.
The Levelogger 6 Junior records absolute pressure using the same durable Hastelloy® pressure sensor as the Levelogger 6. The Hastelloy sensor performs well in harsh environments and withstands 2 times the overpressure without permanent damage.
The Levelogger 6 Junior’s memory holds up to 75,000 sets of temperature and water level data. It records readings at userdefined intervals from 0.5 seconds to 99 hours. Accuracy is 0.1% FS with lifetime factory calibration.
Features
- Low cost
- Robust Hastelloy pressure sensor
- Memory for 75,000 data points with dedicated backup
- 5-year battery life (based on 1 reading per minute)
- Works with all Levelogger 6 Series accessories
- 2X communication speed with new PC Interface Cable
Applications
- Monitoring water levels in wells and surface water
- Pump and slug tests
- Reservoir and stormwater runoff management
- Watershed and drainage basin monitoring
- Stream gauging, lake and wetland monitoring
- Tank level measurement
| Models | Full Scale (FS) | Accuracy | Resolution |
| M5 | 5 m (16.4 ft) | ± 0.5 cm, 0.016 ft. | 0.02% FS |
| M10 | 10 m (32.8 ft) | ± 1.0 cm, 0.032 ft. | 0.01% FS |
| Pressure Transducer | Piezoresistive Silicon with Hastelloy Sensor |
| Calibrated Ranges | 5, 10 m |
| Accuracy | ± 0.1% FS |
| Resolution | 0.02% FS to 0.01% FS |
| Units of Measure | cm, m, ft, psi, kPa, bar, (ºC, ºF) |
| Normalization | Automatic Temperature Compensation |
| Calibration | Factory – Lifetime calibration |
| Response Time (90% Thermal ∆) | 1 minute/1ºC change |
| Temp Comp Range | 0 to +40°C |
| Over-pressure Range | 2 X |
| Temperature Sensor | Platinum Resistance Temperature Detector (RTD) |
| Temperature Accuracy | ± 0.1°C |
| Temperature Resolution | 0.1°C |
| Operating Temp Range | -20 to +80°C |
| Clock Accuracy (typical) | ± 1 minute / year (-20ºC - +80ºC) |
| Battery Life | 5 Years (based on 1 reading/minute) |
| Size | 22 mm x 160 mm (7/8" x 6.3") |
| Weight | 145 grams (5.1 oz) |
| Memory | 75,000 sets of readings (separate dedicated backup for latest 500 readings) |
| Communication Speed (baud) | 9600, 57600 with USB Desktop/Field Reader, 19.2k with Mk3 USB-C PC Interface Cable |
| Com Interface | Optical high-speed: USB, SDI-12, MODBUS* |
| Memory Modes | Continuous or Slate |
| Logging Rates | 0.5 sec to 99 hours |
| Logging Modes | Linear, Real Time View, Future Start |
| Barometric Compensation | Data Wizard and Barologger 6 |
| Corrosion Resistance | 316L Stainless Steel and Hastelloy Sensor |
| Wetted Materials | Delrin, Viton, Hastelloy, 316L Stainless Steel |
*SDI-12 and MODBUS communication requires a surface Interface Cable for operation.














Do you have a question?