New
    Ultra-low temperature freezersUltra-low temperature freezersUltra-low temperature freezersUltra-low temperature freezersUltra-low temperature freezersUltra-low temperature freezersUltra-low temperature freezers

Ultra-low temperature freezers with climate-neutral refrigerants


View Quote

Fast response from our specialists

Why buy from Geneq? - find out more


Do you have a question?

Ultra-low temperature freezers with climate-neutral refrigerants

The BINDER ultra low temperature freezer ensures the safe storage of samples at -90 °C. It combines outstanding environmental friendliness with low energy consumption, convenient operation and an individual safety concept.

Characteristics

  • Temperature range: -90 °C to -40 °C
  • Lowest energy consumption in its class
  • Energy Star certified (depending on version)
  • Powerful cascade compressor cooling unit
  • Environmentally friendly refrigerants R-290 and R-170
  • Thermal insulation with unique long-life VIPs (vacuum insulation panels)
  • Innovative door gasket concept reduces buildup of ice
  • Ergonomic door handle
  • Rust-proof interior made completely of stainless steel
  • Detachable inner doors made of stainless steel
  • Water cooling (depending on version)
  • 3 stainless-steel shelves providing flexible placement
  • Zero-voltage alarm contact for in-house alarm system
  • Internal data logger, measured values can be read out in open format via USB
  • Ethernet interface
  • 2 access ports, Ø 28 mm, rear

Models

UF V 350

UF V 500

UF V 700

Dimensions incl. fittings and connections (inch)

UF V 350

UF V 500

UF V 700

ModelsUF V 350UF V 500UF V 700
Outer dimensions
Width net [mm]7068261110
Height net [mm]196619661966
Depth net [mm]938938938
Internal Dimensions
Width [mm]486606890
Height [mm]130013001300
Depth [mm]605605605
Measures
Interior volume [L]382477700
Net weight of the unit (empty) [kg]226247288
permitted load [kg]160200200
Performance Data Temperature
Temperature range [°C]-90...-40-86...-40-86...-40
Temperature variation at -80 °C [± K]3.52.52.5
Temperature fluctuation at -80 °C [± K]3.51.51.5
Warm-up time during power failure from -80 °C / -122 °F to -60 °C / -76 °F [min]170230250
Electrical data
Nominal power (version 120 V) [kW]1.41.61.6
Nominal power (version 230 V) [kW]1.61.61.6
Nominal power (version 240 V) [kW]1.61.61.6
Environment-specific data
Energy consumption at set-point -80 °C and ambient temperature = 21 °C [kWh/d]7.97.98.1
Fixtures
Number of shelves (std./max.)3/133/133/13