Single Gas Detector

  • Equipped with internal vibrating alarm for high noise areas
  • Secure and accurate history with datalogging option
  • Multi-language support in English, French, German, Spanish, and Portuguese

View Quote

Fast response from our specialists

Why buy from Geneq? - find out more


Designed with durability and comfort in mind, this gas detector monitors for any single gas hazard within its wide range of available toxic gas models.

     

    Quick Specs

    • Size: 1.1 x 2.0 x 3.75 in./ 2.8 x 5.0 x 9.5 cm
    • Weight: 2.9 oz./ 82 g
    • Alarms: visual, vibrating, audible (95dB)- Low, High, TWA and STEL
    • Tests: Sensor integrity, circuitry, battery and audible/visual alarms on activation, battery (continuous)
    • Pump: Compatible with the Sampler motorized pump
    • Typical battery life: 1.5 year battery life (typical) with replaceable 3V battery
    Size1.1 x 2.0 x 3.75 in. / 2.8 x 5.0 x 9.5 cm
    Weight2.9 oz. / 82 g
    Alarms- Visual, vibrating, audible (95dB)
    - Low, High, STEL, TWA
    TestsSensor integrity, circuitry, battery and audible/visual alarms on activation, battery (continuous)
    PumpCompatible with the Sampler motorized pump
    Typical battery life1.5 year battery life (typical) with replaceable 3V battery
    User options
    • Confidence beep
    • Automatic backlight
    • Latching alarms
    • User-settable calibration gas
    • Stealth mode level
    • Passcode protection
    • Calibration past due lockout
    • Automatic O2 calibration
    • Language choices (five)
    Ratings
    • EMI/RFI: Complies with EMC Directive 89/336/EEC
    • IP 66/67
    Certifications and approvals
    • Class I, Div. 1, Gr.  A, B, C, D
      Class II, Div. 1, Gr.  E, F, G
    • American Bureau of Shipping
    • ATEX: CE II 1 G  T4
      Ex ia IIC  T4
    • IECEx:  Ex ia IIC  T4
    • CE : European Conformity
    WarrantyFull two year warranty including sensors (One year NH3, Cl2, O3, ETO, ClO2 sensors)
    GasMeasuring Range (ppm)Operating TemperatureRelative
    Humidity
    (non-condensing)
    H2S0-100-40 to +122°F/-40 to +50°C15% - 90%
    H2S (High Range)0-500-40 to +122°F/-40 to +50°C15% - 90%
    SO20-100.0-40 to +122°F/-40 to +50°C15% - 90%
    HCN0-30.0-40 to +122°F/-40 to +50°C15% - 90%
    CO0-1000-22 to +122°F/-30 to +50°C15% - 90%
    CO (Low H2)0-1000-22 to +122°F/-30 to +50°C15% - 90%
    NH30-100-4 to +104°F/-20 to +40°C15% - 90%
    NH3 (High Range)0-400-4 to +104°F/-20 to +40°C15% - 90%
    Cl20-50.0-4 to +122°F/-20 to +50°C10% - 95%
    NO0-250-4 to +122°F/-20 to +50°C15% - 90%
    NO20-100-4 to +122°F/-20 to +50°C15% - 90%
    PH30-5.0-4 to +122°F/-20 to +50°C15% - 90%
    ETO0-100.0-4 to +122°F/-20 to +50°C15% - 90%
    ClO20-1.0-4 to +122°F/-20 to +50°C15% - 95%
    O30-1.0-4 to +122°F/-20 to +50°C15% - 90%
    O2 (%by Vol.)0-30.0%-4 to +122°F/-20 to +50°C0% - 99%
    Alarm setpoints for all sensors are user adjustable. Setpoints are automatically displayed during instrument start up.