Multi-Gas Detector Transmitter
Ammonia, Carbon monoxide, Carbon dioxide, Chlorine, Ethylene, Ethylene oxide, Formaldehyde, Hydrogen, Hydrogen fluoride, Hydrogen sulphide, Nitric oxide, Nitrogen dioxide, Oxygen, Ozone, Sulfur dioxide, Ethanol, Dimethyl ether, Methanol, Methane, Propane, Hydrogen, TVOCs, Refrigerants
For monitoring: Ammonia, Carbon monoxide, Carbon dioxide, Chlorine, Ethylene, Ethylene oxide, Formaldehyde, Hydrogen, Hydrogen fluoride, Hydrogen sulphide, Nitric oxide, Nitrogen dioxide, Oxygen, Ozone, Sulfur dioxide, Ethanol, Dimethyl ether, Methanol, Methane, Propane, Hydrogen, TVOCs, Refrigerants
The cGas Detector is a digital, one or two channel gas detection transmitter that offers greater flexibility at a lower cost with customized sensor combinations and specialized options for adding only the functionality you need. It is ideal for monitoring toxic, combustible and refrigerant gases in commercial and light industrial, non-hazardous (non-explosion rated) environments.
Output is user selectable in the field with your choice of BACnet® or Modbus® for communicating with a Controller or a Building Automation System. Pre-calibrated sensors with true Plug & Play Smart Sensor technology makes replacing sensors quick and easy.
Powered by 24 VDC or ground reference AC, the digital cGas Detector it has an LCD display, temperature compensation, thermal resetting fuses and the firmware and configuration can be upgraded in the field using the USB connection. Specialized optional features include, relative humidity and temperature monitoring, low temperature operation, relay and wash-down / water spray protection.
The digital cGas Detector comes in a standard water / dust tight, corrosion resistant ABS / polycarbonate enclosure with a hinged, secured door. With the optional, factory installed standard splash guard the enclosure is IP54 rated and provides protection in water spray or wash down applications.
Features
- Up to 2 gas channel configurations
- User in the field configurable BACnet® MS/TP RS-485 or Modbus® RTU RS-485 digital output signal
- Easy Plug & Play Smart Sensor replacement at end of life, comes pre-calibrated
- Bright LCD display
- USB port for configuration changes and firmware upgrades
- Internal 2A SPDT dry contact relay with or without internal buzzer (Option -RBZ or Option -RLY)
- Optional RH & Temperature sensor (Option -RHT)
- Optional low temperature operation package (Option -LT)
- Optional factory installed splash guard (Option -S or Option -SN)
- Standard black, ABS/polycarbonate, water / dust tight, corrosion resistant enclosure (drip proof),IP54 with optional splash guard installed
- Sensor Calibrating Extending Firmware (CEF) for enclosed parking applications
- RoHS compliant circuit boards
Applications
- Parking Facilities / Vehicle
- Repair Shops
- Ice Arenas / Swimming Pools
- Refrigeration Rooms / Chiller Rooms
- Battery Charging Rooms
- Manufacturing Plants
- Maintenance Facilities
- Greenhouses
- CO2 Fire Suppression
- CO2 Storage Rooms
- CO2 Refrigeration Systems
- Microdistilleries
- Chemical Plants
- Perfume/Beauty Products
- Manufacturing
- Household Products
- Manufacturing
- Sewage Treatment Facilities
- and many more...
Models
CGAS-D-CO
Single channel, internal electrochemical carbon monoxide (CO) sensor (0 - 200 ppm range),LCD display, in field configurable Modbus RTU RS-485 or BACnet MS/TP RS-485 output, Plug & Play Smart sensor replacement
CGAS-D-CO-NO2
Dual channel, internal carbon monoxide (CO) sensor (0 - 200 ppm range) and nitrogen dioxide (NO2) sensor (0 - 10 ppm),LCD display, in field configurable Modbus RTU RS-485 or BACnet MS/TP RS-485 output, Plug & Play Smart sensor replacement
CGAS-D-SR404A
Single channel solid state refrigerant (R404A) sensor (0 - 2,000 ppm range),LCD display, in field configurable Modbus RTU RS-485 or BACnet MS/TP RS-485 output, Plug & Play Smart sensor replacement
CGAS-D-CO-R
Dual channel, internal carbon monoxide (CO) sensor (0 - 200 ppm range),must add ESH-A remote sensor, LCD display, in field configurable Modbus RTU RS-485 or BACnet MS/TP RS-485 output, Plug & Play Smart sensor replacement
CGAS-D-NO2
Single channel, internal electrochemical (NO2) sensor (0 - 10 ppm range),LCD display, in field configurable Modbus RTU RS-485 or BACnet MS/TP RS-485 output, Plug & Play Smart sensor replacement
Target Gas
Electrochemical Sensors | Ammonia (NH3),Carbon monoxide (CO),Chlorine (CL2),Ethylene (C2H4),Ethylene oxide (C2H4O),Formaldehyde (CH2O),Hydrogen (H2),Hydrogen fluoride (HF),Hydrogen sulphide (H2S),Nitric oxide (NO),Nitrogen dioxide (NO2),Oxygen (O2),Ozone (O3),Silane (SiH4),Sulphur dioxide (SO2) |
Infrared Sensor | Carbon dioxide (CO2) |
Solid State Sensors | Refrigerants R22, R32, R134A, R402A, R404A, R407C, R410A, R422D, R438A, R448A, R449A, R507A, R513A, R514A, TVOCs |
Catalytic Sensors | Ammonia (NH3),Hydrogen (H2),Methane (CH4),Propane (C3H8),Ethanol or Dimethyl Ether (C2H6O),Methanol (CH4O) |
PID Sensors | TVOC |
Mechanical
Enclosure | Black ABS / Polycarbonate, corrosion resistant Copper coated interior to reduce RF interference IP54 rated with standard splash guard installed (Option -S) |
Weight | 400 g / 14 oz |
Size | 127 x 127 x 76 mm / 5.0 x 5.0 x 3.0 inches |
User Interface
Display (standard) | 2-line by 16 character graphic LCD Operating Temp: 0°C to 40°C / 32°F to 104°F |
Display (Option -LT) | 2-line by 16 character OLED display for cold environment applications down to -40°C / -40°F |
Push Buttons | Initiate calibration and menu options with internal UP, DOWN and ENTER push buttons |
USB Port | Internal port for USB memory stick for field firmware / configuration upgrades |
Input/Output
Communication | User configurable in the field, BACnet® MS/TP (version 1 rev 14) RS-485 or Modbus® RTU (version 1.1b3) RS-485 |
RH & Temperature (Option -RHT) | User selectable units DegC or DegF |
Relay & Buzzer* | 1 SPDT relay rated 30 volts, 2 amp max with internal buzzer rated 90 dB @ 10 cm / 4 in, enable/disable |
Relay (Option -RLY) | 1 SPDT relay rated 30 volts, 2 amp max |
Electrical
Power Requirement | 16-30 VDC, 3 W*, Class 2 *dependent on sensor type 12-27 VAC, 50-60 Hz, 3 VA*, Class 2 *dependent on sensor type |
Wiring | VDC or VAC (ground referenced) 4-conductor shielded 16 AWG stranded within conduit, network wiring (daisy-chain) |
Fuse(s) | Automatic resetting thermal |
Environmental
Operating Temperature | 0°C to 40°C (32°F to 104°F),temperatures below 0°C / 32°F require Option-LT |
Operating Humidity | 15 - 90% RH non-condensing |
Certifications
Conforms to | CSA-C22.2 No. 205-12, UL508 (Edition 18):2018 EMC Directive 2014/30/EU, EN 50270:2015, Type 1, EN61010 FCC. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Listed by BTL RoHS compliant circuit boards |
CO and NO2 Sensor Complies with | UL2075, 2nd Edition, Standard for Gas and Vapour Detectors and Sensors |
Can we help you?
min 10 ch