Environment
 
    High-speed Data Logger

High-speed Data Logger

8 multifunction channels


View Quote

Fast response from our specialists

Why buy from Geneq? - find out more


High-Speed Simultaneous Voltage and Temperature Measurements

Portability is the key focus at Graphtec Instruments.  As variation and quality become the main factor for improvements in product development, manufacturing companies are implementing more and more testing processes that involve strenuous cycles and long term measurement with multiple channels of information that comes from various sensors with as many frequency as possible.  From drop testing to NVH testing, environmental testing, life cycle and stress testing, Graphtec GL900 provides a versatile and lightweight datalogger signals that caters to the most advanced research and development in the world and to every day testing at the palm of your hand.

Easy-to-use upright high-speed isolated 8-channel multifunction logger reads; AC, DC voltage, process current, flow, pressure, and temp measurements.

Modern conveniences such as Ethernet and USB 2.0 interfaces are included so you can easily get the data out of your GL900 and transfer it to your computer. Data is normally captured into the GL900’s large internal flash memory (256MB),at rates selectable from 10μ to 60s.  

8 x voltage inputs with channel isolation, BNC connectors or M3 screw terminal inputs.


Main Features

  • GL900 has a bright 5.7" color TFT-LCD display
  • Built-in Ethernet 100Tx and USB 2.0 interfaces
  • Accepts voltages, thermocouples and humidity
  • 8 channels measure voltage, current and temperature
  • Electrical isolation per channels
  • High-speed sampling (depends on destination memory; internal RAM, flash, or external USB flash drive) sample rates as fast as 100,000 Hz are supported.
  • Real-Time-Calculations.  GL900 can calculate average value, peak value, minimum value, and RMS.
  • Voltage input levels: 20mV to 500V F.S.
  • Thermocouple input types: B, R, S, T, N, K, W, E, J
  • Continuous battery charge during operation
  • 256MB internal flash memory
  • Includes 4 pulse logic inputs, 1 trigger input
  • Includes 4 x alarm outputs.  GL900 trigger its open-collector outputs as a function of analog input signal level judgment, pulse judgment, or logic pattern.
  • Compact data logger footprint (232mm x 150mm x 80mm)
  • Flexible power requirements.  GL900 provided international AC adaptor, from optional built-in battery pack, or from any 9 to 24 VDC source with using an optional cable.
  • Includes APS Windows software for setup, control, data transfer, data conversion to ASCII and Excel formats, and on-screen data review with cursors

Electrical Isolation Offers Accurate Measurements

Where grounding issues pose significant impact in Industrial and R&D applications, GL900 offers high electrical isolation in between channels to offer accurate recording of your data.

Bright 5.7" TFT-LCD Display

Views can be narrowed down and expanded using one-stop Time/DIV button.  

Brightly colored TFT-LCD display allows handheld portability to display real time graphic waveform during data acquisition.  Post-processing data can be reviewed and saved onto external media (USB memory) using the navigation panel on the GL900.

Dedicated Software Offering Real-Time Data Capturing and More

Software can be connected using LAN/USB interface with remote configuration and real time display view.  Additional analysis tools include Excel output, XY plotting, and frequency analysis of fast moving signals.

20MV to 500V Full-Scale Measurements with 4-Alarm Outputs

GL900 offers full-scale max 500V DC and AC data recording capability with max 100KS/s for all 8 channels.  RMS data is also readable using the statistical value views post-processing.  For high glitch voltage measurement, GL900 offers a versatile portability for your field testing needs.

ItemDescription
GL900-8GL900-4
No. of analog input ch.8 ch4 ch
External input/outputTrigger input (1 channel),Logic input (4 channels) or Pulse input (4 channels),Alarm output (4 channels)
Sampling interval10μs to 1 min
TIME/DIV10 ms/DIV to 24 hour/DIV
Timer functionsDate and time, daily cycle, hourly cycle
Trigger functionsTypeStart: Data capture starts when a trigger is activated; Stop: Data capture stops when a trigger is activated
ConditionStart: Off, Input signal level (analog, logic/pulse),External*1, Scheduled time
Stop: Off, Input signal level (analog, logic/pulse),External *1, Scheduled time
CombinationInput signal level: Level OR, Level AND, Edge OR, Edge AND
ModeH (Rising),L (Falling),Window In*2, Window Out*2
Alarm setting functionsRising, Falling, Window In*2, Window Out*2
Alarm output *1Number of channels: 4, Open collector output (5V, 10 kΩ pull-up resistance)
Pulse input*1, *3RPM mode50 to 20 M RPM/F.S. (in steps of 1, 2, or 5)
Count mode50 to 20 M C/F.S. (in steps of 1, 2, or 5)
Inst. Mode50 to 20 M C/F.S. (in steps of 1, 2, or 5)
Calculation functionsStatistical calculations *4: Average, Peak, Maximum, Minimum, RMS (2 calculations can be set simultaneously)
Other functionsSearch function, annotation input function
PC intefaceEthernet (10BASE-T/100BASE-TX),USB (High Speed supported) provided as standard
Ethernet functionsWeb server function, FTP server function, NTP client function
USB functionUSB drive mode (File transfer and deletion from internal GL900 memory)
Memory deviceInternalOne million data points / Internal flash memory:Approx. 256 MB
ExternalUSB memory slot (High speed supported) *5
Display screensWaveforms + digital values, enlarged waveforms, digital values + calculation results, X-Y
Display unit5.7-inch TFT color LCD
Operating environment0 to 40℃, 5 to 85% R.H. (15 to 35℃ when using batteries)
Withstand voltageBetween each input channel and GND: 1000 V p-p for one minute, between input terminals: 1000 Vp-p for one minute
Power supplyAC adapter100 to 240 VAC, 50 to 60 Hz
DC input8.5 to 24 VDC
Battery pack *6Option
   
Power consumption42VA (when operating and charging battery with AC power)40VA (when operating and charging battery with AC power)
External dimensions232 x 150 x 80 mm (W x H x D),approx.
Weight (approx.)1.1 kg (excluding AC adapter and battery)1.0 kg (excluding AC adapter and battery)
Vibration-tested conditionsEquivalent to automobile parts Type 1 Category A classification

*1. Logic alarm cable (B-513) is required.
*2. Cannot be set for logic input
*3. Maximum input frequency: 50 kHz, maximum number of counts: 15 M C
*4. In real time or when Between Cursors has been specified (during Replay)
*5. 1 file = 2 Gbytes (depends on the USB memory stick used)
*6. Please install two battery packs.