Waterproof Portable pH Meters
- Hanna instruments - HI9124 - HI9125
- Designed to provide laboratory precision and accuracy under harsh environmental and industrial conditions.
The HI9124 and HI9125 are rugged, waterproof, portable pH meter and the HI9125 is also a mV meter.
These meters offer many features including automatic calibration, automatic shut off, battery error prevention system, on-screen instructions, and automatic temperature compensation. They are supplied complete with meter, PEI plastic body, double junction pH electrode, and temperature probe packaged in a durable plastic carrying case.
- Automatic Two-Point Calibration
- Automatic Temperature Compensation
- Waterproof to IP67 Standards
They are designed to provide laboratory precision and accuracy under harsh environmental and industrial conditions. These meters offer a variety of features including automatic calibration to 1 or 2 points, automatic temperature compensation, backlit (HI9124) or dual-level (HI9125) LCD, on-screen instructions, and Battery Error Prevention System.
HI9125
The HI9125 has selectable pH and mV modes. The mV mode is used with an optional ORP electrode for the determination of oxidation or reduction potentials of a solution. Hanna offers a variety of ORP electrodes from glass to PEI plastic body styles.
The HI9124 and HI9125 uses the universal BNC probe input for their electrodes. The universal BNC connector allows the user to select from a wide variety of electrodes based on their particular application. A separate RCA connector is used for a thermistor temperature probe. The temperature probe provides for a high ±0.4°C accuracy measurement for precise temperature compensation.
Features at a Glance
One or Two-Point Calibration
Automatic calibration can be performed at 1 or 2 points using the 5 preprogrammed buffers (pH 4.01, 6.86, 7.01, 9.18, and 10.01).
On-Screen Instructions
Clear and easy to use on-screen instructions take you through all of the steps in performing a calibration and taking measurements.
Durable Plastic Body pH Electrode
The HI9125 is supplied with the HI1230B PEI plastic body, double junction pH electrode that is gel filled. The PEI body offers excellent chemical resistance to many harsh chemicals. The double junction design helps minimize contamination of the inner reference cell which could cause precipitation of the Ag/AgCl electrolyte resulting in a clogged junction. Since the HI1230B is gel filled it does not require electrolyte solution to maintain.
Temperature Compensation
The HI9125 offers automatic or manual temperature compensation of pH measurements over a wide range from -20.0 to 120.0°C.
mV mode
The HI9125 has a mV mode that can be used with a wide variety of ORP electrodes for monitoring oxidation reduction potentials.
Measurement Recall
The HI9125 has a “MEM” button to store a reading. The reading can be recalled at anytime by pressing the memory recall “MR” button
Automatic Shut-Off
The HI9125 has an adjustable auto-off feature. The meter can be set to turn itself off after 20 minutes to prevent accidental drainage of the batteries or it can be disabled so the user has to turn the meter off with the power button.
Battery Error Prevention System (BEPS)
The Battery Error Prevention System detects when the batteries become too weak to ensure reliable measurements.
HI9124 | HI9125 | |
pH Range | -2.00 to 16.00 pH | |
---|---|---|
pH Resolution | 0.01 pH | |
pH Accuracy | ±0.01 pH | |
pH Calibration | automatic, one or two-point with five memorized buffer values (pH 4.01, 6.86, 7.01, 9.18, 10.01) | |
mV Range | - | ±699.9 mV; ±1999 mV |
mV Resolution | - | 0.1 mV; 1 mV |
mV Accuracy | - | ±0.2 mV; ±1 mV |
Temperature Range | -20.0 to 120.0 ºC, -4.0 to 248.0 °F | |
Temperature Resolution | 0.1 °C, 0.1 °F | |
Temperature Accuracy | ±0.4°C; ±0.8°F | |
Temperature Compensation | manual or automatic from -20.0 to 120.0°C (-4.0 to 248.0°F) | |
Slope Calibration | from 80 to 108% / ±1 pH | |
pH Electrode | HI1230B PEI body pH electrode with BNC connector and 1 m (3.3’) cable (included) | |
Electrode/Probe | HI7662 stainless steel temperature probe with 1 m (3.3’) cable (included) | |
Input Impedance | 10¹² Ohms | |
Battery Type / Life | 1.5V (3) AAA / approximately 200 hours of continuous use | |
Auto-off | after 20 minutes of non-use (can be disabled) | |
Environment | 0 to 50°C (32 to 122°F); RH max 100% | |
Dimensions | 185 x 72 x 36 mm (7.3 x 2.8 x 1.4”) | |
Weight | 300 g (10.6 oz.) | |
Ordering Information | Both supplied with HI1230B pH electrode, HI7662 temperature probe, HI70004 pH 4.01 buffer solution sachet (20 mL),HI70007 pH 7.01 buffer sachet (20 mL),100 mL plastic beaker, 1.5V AAA batteries (3),instructions, and hard carrying case. | |
Warranty | 2 years (probe 6 months) |