    Nutrient and water quality meter Imacimus Agro Series

Nutrient and water quality meter Imacimus Agro Series

  • Input/Measure channels: 8 Channels
  • Measurement range from -2500 mV to 2500 mV.
  • Input impedance of 1e12 Ohms.

View Quote

Fast response from our specialists

Why buy from Geneq? - find out more


AN INDISPENSABLE TOOL IN THE PRECISION AGRICULTURE


IMACIMUS Multi ION allow for quick and reliable ion measurement. Based on the most advanced analytical technology thanks to the patented NT Sensors research on Carbon Nanotubes.

Simultaneously Measure and display 10 Parameters (7 ions/nutrients/ pH /conductivity/ water hardness) in Real Time. An indispensable tool to manage overall level of ionic in the precision agriculture.


Technical features

  • Input/Measure channels: 8 Channels
  • Measurement range from -2500 mV to 2500 mV.
  • Input impedance of 1e12 Ohms.
  • Resolution of 0.1 mV.
  • Working temperature: from 0º C to 70º C.
  • Dimensions 155 x 90 x 35 mm.
  • Weight 240 g.
  • ABS enclosure
  • Multipin connector (for Multi Ion probe input) / or USB connector
  • BNC Connector (for Combination pH electrodes)
  • Mini USB female connector type AB (for power supplying/communication to PC).


    Software System requeriments

    • Windows XP, Windows Vista, 7/8/10 or higher.
    • Net Framework 4 o later (official link).
    • IMA CIMUS Software (download from the NT Sensors site).
    • Available USB port.
    • Mouse and keyboard are required.
    • The instrument is powered directly from the USB port connected to the PC, so it does not require any additional power supply.


    MultiProbe



    Electrode assembly for Software configuration




    Electrodes specifications

    MODULAR ELECTRODE / Mini ION 4.6 / Modular RE

      Body material: PVC

      Diameter 4,6mm

      Length 50mm



      ELECTRODESlope mV/ decadeLineal RangeResponse timepH rangeAccuracy
      *
      Repeatibility
      **
      Main interferences Selectivity coefficient
      AMMONIUM54±5 mV5x10-6...0,5 M
      0.09...9.000
      mg/l
      < 60”4…8.5±4%±10%
      K(NH4+, K+ )= 10-1.0 , K(NH4+ + Ca2+)= 10-4.0
      K(NH4+ + Na+)= 10-2.9, K(NH4+
      , Mg2+ )= 10-3.2
      BROMIDE-54±5 mV0.4…8.000 mg/l< 60”1…12±4%±10%
      Trace of Ag, S o Hg. To avoid I- and CN-
      At less degree OH- (10-4,5)
      and Cl- (10-2.7)
      CALCIUM24±5 mV1x10-5...0,1 M
      0.4...4.000
      mg/l
      < 60”3.5…8±8%±20%
      KCa2+ H+= 10-2.9 / KCa2+ Na+= 10-3.7
      KCa2+ K+= 10-3.6 / KCa2+
      NH4+= 10-3.0
      CHLORIDE-54±5 mV0.5 mg/l 1,3…35.000 mg/l< 60”2…12±4%±10%
      Iodide ions irreversibly damage the membrane. Will not give reliable readings if more than a trace of Ag or S ions are present in the
      solution.
      COPPER#ERREUR!0.06…3.000
      mg/l
      <30”>10ppm
      <5’ <10ppm
      2…7±8%±20%
      Unreliable results in presence of Ag, S or H. Br and Cl ions will interfere if their concentration is
      comparable to copper ions
      FLUORIDE-54±5 mV1x10-6 – 1 M
      0.02 – 19.000
      mg/l
      < 60”4…8±4%±10%
      Only hydroxide ion (OH-) affects to the fluoride measurement. To eliminate this interference, pH must be kept below 8.
      Due to the high complexation of F ions in real samples, a special
      TISAB must be used-
      IODIDE-54±5 mV0.1…10.000
      mg/l
      < 60”2…12±4%±10%
      Trace of Ag, S o Hg. To avoid CN-
      In less significance Br 10-3,4
      y Cl-10-6
      LITHIUM54±5 mV1.4x10-5...0,7 M
      0.1...5.000
      mg/l
      < 60”2…12±4%±10%
      K (Li+, Na+ )=10-2,3 / K( Li+, K+ ==10-2.4 K (Li+, H+ )= 10-
      3.0
      MAGNESIUM24±5 mV1x10-4...0,1 M
      2.4...2.400
      mg/l
      < 120”3...8.5±8%±20%
      K (Mg2+, K+ )=10-3.6 ; K (Mg2+, Ca2+ )= 10-1.0
      NITRATE-54±5 mV1x10-5...0,5 M
      0.6...31.000
      mg/l
      < 60”2...11±4%±10%
      K(NO3- , Br- )= 10-1.5 , K (NO3- , NO2- )= 10-1.7
      K (NO3- , OH- )= 10-1.8 , K(
      NO3- , CH3COO- )= 10-2.2
              
      NITRITE-53.6 ±5
      mV
      0.5…1.000 mg/l< 120”4...8±4%±10%
      K(NO2- , SCN- )= 10-0.2 ,
      K(NO2- , ClO4- )= 10-2.4
      K(NO2- , I- )= 10-2.2 , K(NO2- , Br- )= 10-3.3
      PERCHLORATE-54±5 mV0.1…10.000
      mg/l
      < 60”1...11±4%±10%
      K (ClO4-, SCN-)= 10-1.7 , K
      (ClO4-, I-)= 10-1.7
      K (ClO4-, NO3-)= 10-1.7
      POTASSIUM54±5 mV1x10-5 0.1 M
      0.3...39000
      mg/l
      < 60”1...9±4%±10%
      K (K+,NH4+ )=10-2,1 ; K( K+, Li+
      )=10-4.3
      K (K+, Na+ )=10 -4.6 K
      (K+,Ca2+ )= 10-3.9
      SODIUM54±5 mV1x10-4...1 M
      2.3...23.000
      mg/l
      < 60”1…9±4%±10%
      K (Na+, Li+ )= 10-3.2 , K(Na+, K+
      )= 10-2.5
      K(Na+, Ca2+ )= 10-4.0
      SILVER54±7 mV1x10-6 0.1 M
      0.1...10.000
      mg/l
      < 60”1…9±4%±10%
      Can not work on presence of S2- o Hg2+
      * In absence of interfering ions, precision can be better than ±1mV can be obtained, that corresponds to the ±4% of the measurement. (For divalent ions, ±2mV; ±8%) ** Repeatability in measurement of a standard solution after calibration