Nutrient and water quality meter Imacimus Agro Series
- Imacimus - B257USB
- Input/Measure channels: 8 Channels
- Measurement range from -2500 mV to 2500 mV.
- Input impedance of 1e12 Ohms.
AN INDISPENSABLE TOOL IN THE PRECISION AGRICULTURE
Simultaneously Measure and display 10 Parameters (7 ions/nutrients/ pH /conductivity/ water hardness) in Real Time. An indispensable tool to manage overall level of ionic in the precision agriculture.
Technical features
- Input/Measure channels: 8 Channels
- Measurement range from -2500 mV to 2500 mV.
- Input impedance of 1e12 Ohms.
- Resolution of 0.1 mV.
- Working temperature: from 0º C to 70º C.
- Dimensions 155 x 90 x 35 mm.
- Weight 240 g.
- ABS enclosure
- Multipin connector (for Multi Ion probe input) / or USB connector
- BNC Connector (for Combination pH electrodes)
- Mini USB female connector type AB (for power supplying/communication to PC).
- Windows XP, Windows Vista, 7/8/10 or higher.
- Net Framework 4 o later (official link).
- IMA CIMUS Software (download from the NT Sensors site).
- Available USB port.
- Mouse and keyboard are required.
- The instrument is powered directly from the USB port connected to the PC, so it does not require any additional power supply.
MultiProbe
Electrode assembly for Software configuration
Electrodes specifications
MODULAR ELECTRODE / Mini ION 4.6 / Modular RE
Body material: PVC
Diameter 4,6mm
Length 50mm
ELECTRODE | Slope mV/ decade | Lineal Range | Response time | pH range | Accuracy * | Repeatibility ** | Main interferences Selectivity coefficient |
AMMONIUM | 54±5 mV | 5x10-6...0,5 M 0.09...9.000 mg/l | < 60” | 4…8.5 | ±4% | ±10% | K(NH4+, K+ )= 10-1.0 , K(NH4+ + Ca2+)= 10-4.0 K(NH4+ + Na+)= 10-2.9, K(NH4+ , Mg2+ )= 10-3.2 |
BROMIDE | -54±5 mV | 0.4…8.000 mg/l | < 60” | 1…12 | ±4% | ±10% | Trace of Ag, S o Hg. To avoid I- and CN- At less degree OH- (10-4,5) and Cl- (10-2.7) |
CALCIUM | 24±5 mV | 1x10-5...0,1 M 0.4...4.000 mg/l | < 60” | 3.5…8 | ±8% | ±20% | KCa2+ H+= 10-2.9 / KCa2+ Na+= 10-3.7 KCa2+ K+= 10-3.6 / KCa2+ NH4+= 10-3.0 |
CHLORIDE | -54±5 mV | 0.5 mg/l 1,3…35.000 mg/l | < 60” | 2…12 | ±4% | ±10% | Iodide ions irreversibly damage the membrane. Will not give reliable readings if more than a trace of Ag or S ions are present in the solution. |
COPPER | #ERREUR! | 0.06…3.000 mg/l | <30”>10ppm <5’ <10ppm | 2…7 | ±8% | ±20% | Unreliable results in presence of Ag, S or H. Br and Cl ions will interfere if their concentration is comparable to copper ions |
FLUORIDE | -54±5 mV | 1x10-6 – 1 M 0.02 – 19.000 mg/l | < 60” | 4…8 | ±4% | ±10% | Only hydroxide ion (OH-) affects to the fluoride measurement. To eliminate this interference, pH must be kept below 8. Due to the high complexation of F ions in real samples, a special TISAB must be used- |
IODIDE | -54±5 mV | 0.1…10.000 mg/l | < 60” | 2…12 | ±4% | ±10% | Trace of Ag, S o Hg. To avoid CN- In less significance Br 10-3,4 y Cl-10-6 |
LITHIUM | 54±5 mV | 1.4x10-5...0,7 M 0.1...5.000 mg/l | < 60” | 2…12 | ±4% | ±10% | K (Li+, Na+ )=10-2,3 / K( Li+, K+ ==10-2.4 K (Li+, H+ )= 10- 3.0 |
MAGNESIUM | 24±5 mV | 1x10-4...0,1 M 2.4...2.400 mg/l | < 120” | 3...8.5 | ±8% | ±20% | K (Mg2+, K+ )=10-3.6 ; K (Mg2+, Ca2+ )= 10-1.0 |
NITRATE | -54±5 mV | 1x10-5...0,5 M 0.6...31.000 mg/l | < 60” | 2...11 | ±4% | ±10% | K(NO3- , Br- )= 10-1.5 , K (NO3- , NO2- )= 10-1.7 K (NO3- , OH- )= 10-1.8 , K( NO3- , CH3COO- )= 10-2.2 |
NITRITE | -53.6 ±5 mV | 0.5…1.000 mg/l | < 120” | 4...8 | ±4% | ±10% | K(NO2- , SCN- )= 10-0.2 , K(NO2- , ClO4- )= 10-2.4 K(NO2- , I- )= 10-2.2 , K(NO2- , Br- )= 10-3.3 |
PERCHLORATE | -54±5 mV | 0.1…10.000 mg/l | < 60” | 1...11 | ±4% | ±10% | K (ClO4-, SCN-)= 10-1.7 , K (ClO4-, I-)= 10-1.7 K (ClO4-, NO3-)= 10-1.7 |
POTASSIUM | 54±5 mV | 1x10-5 0.1 M 0.3...39000 mg/l | < 60” | 1...9 | ±4% | ±10% | K (K+,NH4+ )=10-2,1 ; K( K+, Li+ )=10-4.3 K (K+, Na+ )=10 -4.6 K (K+,Ca2+ )= 10-3.9 |
SODIUM | 54±5 mV | 1x10-4...1 M 2.3...23.000 mg/l | < 60” | 1…9 | ±4% | ±10% | K (Na+, Li+ )= 10-3.2 , K(Na+, K+ )= 10-2.5 K(Na+, Ca2+ )= 10-4.0 |
SILVER | 54±7 mV | 1x10-6 0.1 M 0.1...10.000 mg/l | < 60” | 1…9 | ±4% | ±10% | Can not work on presence of S2- o Hg2+ |