Environment
 
    Low Pressure Packers

Low Pressure Packers

Ideal for isolating discrete zones for various groundwater sampling and monitoring applications.

View Quote

Fast response from our specialists

Why buy from Geneq? - find out more


These simple inexpensive packers inflate with a hand pump and are available in 1.8" and 3.7" (46 mm and 94 mm) diameters.

Primarily for use in 2" and 4" (50 mm and 100 mm) monitoring wells, they can also be used in smooth boreholes and wells with 1.9 - 5" (48 - 127 mm) inside diameters. Typical inflation pressures for the 1.8" (46 mm) packers are from 20 - 40 psi (140 - 345 kPa) above hydrostatic pressure, and from 20 - 30 psi (140 - 205 kPa) for the 3.7" (94 mm) packers.
The Packers utilize a gland of black carbon reinforced rubber (BCR) on a Sch 80 PVC body. They are lowered on flexible low density polyethylene (LDPE) tubing or a rigid PVC drop pipe. If a rigid drop tube is not required for your application, it is recommended to attach a safety line to the eyebolt provided. The Solinst Model 103 Tag Line provides a convenient, graduated support cable that can be used for this purpose, as well as for measuring placement depth. The inflation line of 1/8" (3 mm) low density polyethylene (LDPE) is easily attached using the nylon compression fittings on each packer.

Single or Straddle Packers

Solinst packers are ideal for use with Bladder Pumps or Double Valve Pumps, which can be easily attached above the packers. The water inlet can be below a single packer, or through perforated pipe fitted between straddle packers. For hydraulic conductivity testing, Solinst Leveloggers can also be suspended, either below or between packers, from the eyebolt on the bottom of the packer.

 

  • Perforated Straddle Pipe
  • Inflation Valve Assembly
  • Inflation Tubing 1/8" OD LDPE
  • Tag Line (Model 103 - marked support cable)
  • Water Level Meter (Models 101, 102)
  • Pumps (Models 404, 407, 408, 410)
  • Leveloggers (Model 3001)
  • Inflation Pump

 

Applications

Isolating discrete zones for:

  • Water sampling
  • Hydraulic conductivity testing
  • Datalogging with a Levelogger
  • Minimizing purge volumes
  • Reducing well development time
  • Slug and pump tests
  • Injection of tracers, amendments or other materials
  • Air sparging (low pressure)

Accessories & Optional Equipment

• Perforated Straddle Pipe • 800 or 800M Inflation Valve Assembly

• 1/4" OD LDPE Inflation Tubing (1/8" OD for 800M)

• Inflation Pump

• Tag Line (Model 103 - marked support cable)

• Water Level Meter (Models 101, 102)

• Pumps (Models 404, 407, 408, 408M, 410, 415 w/ 800M))

• Leveloggers (Model 3001)

    Packer SizeOD 1.8" (46 mm)3.9"(99 mm)
    Access ID1/2" (12.7 mm)1" (25.4 mm)
    Gland Length23" (584 mm)30" (762 mm)
    Overall Length29" (737 mm)36" (914.4 mm)
    - with centralizersSame44" (1,117.6 mm)
    Borehole Size1.9 - 2.4" (48 - 61 mm)4.0 - 4.4" (102 - 112 mm)
    -with centralizers2.5 - 3.5" (63 - 89 mm)4.5 - 5.0" (114 - 127 mm)
    Pipe Fittings1/2" NPT Female1" NPT Male
    -with centralizersSame1" NPT Female