Pressure, Temperature, and Digital Crest Gauge Sensor
- Stevens - Smart PT
- < ± 0.1% full scale accuracy
- Aluminum oxide ceramic membrane
- Digital output (SDI-12 / RS485)
Stevens’ Smart PT is a ceramic membrane pressure and temperature sensor that delivers accurate results for a wide range of fluid level measurement applications
In addition to simple instantaneous measurements, this smart sensor features the ability to capture peak crest levels, and to automatically sample and report basic statistics on a configurable time interval.
A corrosion-resistant stainless steel housing and potted electronics make Smart PT extremely durable and long lasting for submersible water applications.
Smart PT is available with a vented or absolute pressure sensing module. Both versions come equipped with user specified length of cable. The vent tube provides an atmospheric reference which compensates for variations in barometric pressure.
In addition to programmable corrections for local variations in Earth’s gravitational field, Smart PT also compensates automatically for the water temperature-density dependency.
Every Smart PT provides both SDI-12 and RS-485 digital interfaces. Compatible with existing power and data logging instruments, the sensor can easily be deployed for data collection at remote monitoring sites.
Features
- < ± 0.1% full scale accuracy
- Aluminum oxide ceramic membrane
- Digital output (SDI-12 / RS485)
- Depth scales available from 2 meters (6.6 feet) up to 200 meters (660 feet)
- Rugged housing and fully potted electronics - no risk of leaking
- Compact size
- Not damaged by freezing water
- Vented or non-vented cable, user specified length
- Direct pipe connection option
- Low power consumption
- Lightning protection
- Overpressure tolerant
Unique Abilities
- Average and standard deviation outputs on up to 3600 autosampled data points over configurable time window
- Crest gauge function automatically captures minimum and maximum level
- Smart autosampling can provide smoothing and oversampling
- Custom offsets
- Environmental corrections for local gravitational field and changes in fluid density due to temperature
Supply voltage | 6 - 28 VDC (12 VDC typical) |
Current consumption | Average, SDI-12, one measurement per minute: 0.9 mA |
Output | SDI-12 (Version 1.4) and RS-485 |
Operating temperature | -20 °C to 80 °C (-4 °F to 176 °F) |
Storage temperature | -40 °C to 80 °C (-40 °F to 176 °F) |
Pressure accuracy | ± 0.1% of full scale |
Temperature accuracy | ± 0.25 °C (0.45 °F) |
Wiring | Red: 6 - 28 Vdc, Black: GROUND, Blue: SDI-12, White: RS-485 A/+, Green: RS-485 B/- |
Cable | High durability polyurethane (26 AWG) |
Pipe threading | M14-1 |
Dimensions | 86.4 mm x 22.1 mm (3.4 in x 0.9 in) |
Body material | 316L Stainless Steel |
Weight | Probe: 120 g (4.23 oz.) |