• Residential Combustion Analyzer

Residential Combustion Analyzer


View Quote

Can we help you?

The testo 310 residential combustion analyzer represents a new class of instruments for Testo and provides exceptional value and expanded capabilities in combustion testing.

Right the first time - every time.

The 310 sets a new standard in reliable combustion tuning with its rugged housing, simple design and advanced sensor technology.
 The easy-to-read backlit display shows more measurements which provides a more complete picture of the combustion process. Simple  top-of-display icons show you the current measurement functions. After only 30 seconds the 310 is ready to test.

Simple to use with reliable results.
The testo 310 eliminates the need for look up charts and the purchase and disposal of expensive chemicals. The kink-resistant hose is integrated into the housing to eliminate leaks. The stainless steel probe and cone-stop is perfect for residential furnace, boiler and water heater applications. With five diff erent fuels to select from, it provides the flexibility you need for your tuning opportunities.


Faster, productive - tune ups, maintenance and more...
Whether you need to perform basic or more complex combustion tuning, perform maintenance or safety checks, or install new combustion units, the fully featured testo 310 delivers more combustion parameters. Use the 310 for accurate heating adjustment so you can get it right the fi rst time - every time.

 

Features

  • O 2 , CO (w/ NOx fi lters standard),CO 2
  • Draft & Pressure
  • Temperature (fl ue & ambient)
  • Combustion effi ciency & excess air
  • Undiluted CO (CO air free)
  • Ambient CO

 

Specifications

ParameterMeasuring RangeAccuracyRésolutionTime Setting t90
Temperature
(combustion)
0 ... +400 °C± 1 °C (0 ... +100 °C)
± 1.5 % v.m. (>100 °C)
0.1 °C˂ 50 sec
Temperature
(ambiant)
-20 ... +100.0 °C± 1 °C0.1 °C˂ 50 sec
Mesure du tirage-20 ... +20 hPa± 0.03 hPa (-3.00 ... +3.00 hPa)
± 1.5 % v.m. (étendue restante)
0.01 hPa 
Mesure de pression-40 ... 40 hPa± 0.5 hPa0.1 hPa 
Range O 2 0 ... 21 %Vol.± 0.2 %Vol.0.1 %Vol.30 sec.
Range CO
(without
compensation H2 )
0 ... 4000 ppm± 20 ppm (0 ... 400 ppm)
± 5 % v.m. (401 ... 2000 ppm)
± 10 % v.m. (2001 ... 4000 ppm)
1 ppm60 sec.
Range CO
ambiant
0 ... 4000 ppm± 20 ppm (0 ... 400 ppm)
± 5 % v.m. (401 ... 2000 ppm)
± 10 % v.m. (2001 ... 4000 ppm)
1 ppm60 sec.
Efficiency Calculation
(Eta)
0 ... 120 % 0.1 % 
Losse Fumes0 ... 99.9 % 0.1 % 


 

General Specifications

Storage Temp.-20 ... +50 °C
Service Temp.-5 ... +45 °C
AlimentationAccumulateur : 1500 mAh ; bloc
d’alimentation : 5V/1A
MemoryAucune mémoire
DisplayEcran éclairé ; 2 lignes
Weight with Probeenv. 700 g
Dimensions201 × 83 × 44 mm