Aquamate 7100 vis & 8100 UV-Vis
- Thermo Scientific - AQ7000-AQ8000
- Easy operation using the 260+ preprogrammed methods for common colorimetric reagents
- Easy access to approved regulatory methods for wastewater and drinking water.
- Secured Smart Method selection for frequently used methods
Spectrophotometers for water and wastewater analysis
Built on the foundation of 60 years of spectroscopy experience, the next generation Orion AquaMate Spectrophotometers combine exceptional performance with a contemporary design Thermo Scientific™ Orion™ AquaMate™ 7100 Visible and
8100 UV-Visible Spectrophotometers are designed to meet the specific needs of water and waste water analysis laboratories.
Thermo Scientific™ Orion™ AquaMate™ Vis and UV-Vis spectrophotometers offer the following
features and benefits:
- Easy operation using the 260+ preprogrammed methods for common colorimetric reagents
- Easy access to approved regulatory methods for wastewater and drinking water.
- Secured Smart Method selection for frequently used methods
- Glove-friendly touchscreen user interface.
- Flexibility to create new methods for additional reagents or samples – create new methods using calibration standards or update methods using published wavelengths and equations
- Use a variety of circular and rectangular vial sizes with a variety of vial holder options.
- Performance verification tests ensure wavelength accuracy and instrument functionality, plus built-in filters allow for wavelength verification with no additional equipment require
- Additional functions include standard curve concentration measurements, wavelength, scanning, multiple fixed-wavelength measurements, absorbance ratio and difference
- One year instrument warranty
Orion AquaMate 7100 Spectrophotometer Vis
The Orion AquaMate 7100 Vis spectrophotometer measures in the wavelength range of 325 to 1100 nm.
using a tungsten halogen lamp, designed for easy replacement using the factory prealigned lamp and base. The tungsten halogen lamp has an average life of more than
1,000 hours.
Orion AquaMate 8100 UV-Vis Spectrophotometer
The Orion AquaMate 8100 UV-Vis spectrophotometer measures in the 190 nm to 1100 nm.
wavelength range using a Xenon Flash lamp that requires no warm-up time and is designed for an average 3-5 year lifespan.
Preprogrammed test methods
Orion AquaMate 7100 Visible and 8100 UV-Visible
Spectrophotometers include over 260 preprogrammed methods for easy and convenient measurements using Thermo Scientific™ Orion™ AQUAfast™, Merck, and CHEMetrics reagents.
The preprogrammed test methods allow simple, accurate analysis of acid capacity, alkalinity, aluminum, ammonia, ammonium, antimony, AOX, arsenic, BOD, boron, bromine, cadmium, calcium, chloride, chlorine, chlorine dioxide, chromate, chromium, COD, color, copper, cyanide, cyanuric acid, DEHA, detergents, dissolved oxygen, fluoride, formaldehyde, gold, hardness, hydrazine,hydrogen peroxide, iodine, iron, lead, magnesium, manganese, mercury, molybdate, molybdenum,
monochloramine, nickel, nitrate, nitrite, nitrogen, oxygen, oxygen scavengers, ozone, palladium, pH, phenol, phosphate, platinum, potassium, silica, silver, sodium,
sulfate, sulfide, sulfite, surfactants, suspended solids, tin, TOC.
Volatile organic acids and zinc can also be measured using Orion AQUAfast, Merk, and CHEMetrics reagents and assorted vial sizes. The instruments allow a one point
adjustment on any preprogrammed method to correct for variations in batch reagent chemistries. Preprogrammed methods can also be adapted for new chemistries or operators can create their own custom methods.
All preprogrammed methods are preloaded on the included USB memory stick to allow operators to add or remove methods as desired. Custom methods using the standard curve function can be uploaded through the USB, making it possible for most colorimetric reagents to be used. Making it possible for most colorimetric reagents to be used. Visit thermofisher.com/aquamateuvvis for the most current
list of US EPA compliant reagent chemistry methods. To aid in loading, transfering and storing methods and data, Orion AquaMate Spectrophotometers feature three
USB connection ports. The ports may be used with a USB memory stick, to transfer data directly to a computer, or to connect to an external printer for printing hard copies of data produced by the spectrophotometer.
Performance verification testing
Orion AquaMate 7100 Visible and 8100 UV-Visible Spectrophotometers include performance verification tests that ensure wavelength accuracy and instrument
functionality. In accordance with GLP and GMP, each verification report gives the time, date and instrument serial number. The built-in wavelength accuracy test
is compatible with either the internal lamp or external calibrated standards.
Variety of vial holder options
The instruments allow the ultimate flexibility in vial sizes and accommodate a wide range of round, square and rectangular vials with three vial holder options. Each vial
holder turret can be easily installed and replaced in the instrument sample compartment.
Magnetically retained, easy to clean vial holders are available for 12 to 25 mm round, 10 mm square and 20 to 100 mm rectangular vials. An adjustable round vial holder is also included/available that accommodates 13 to 24 mm
round vials.
Choice of two models for your water analysis needs
The Orion AquaMate 7100 Visible Spectrophotometer measures a range from 325 to 1100 nm wavelengths for water and wastewater testing. The 5.0 nm spectral
bandwidth is ideal for most routine concentration measurements.
Additional benefits of the Orion AquaMate 7100 Visible
Spectrophotometer include:
- Cost-effective visible only measurements
- Small footprint and lightweight design
- The tungsten-halogen lamp offers 1,000 hours of light testing.
- Similar performance features as the Orion Aquamate
8100 UV-Visible Spectrophotometer
The Orion AquaMate 8100 UV-Visible Spectrophotometer measures a range from 190 to 1100 nm wavelengths for the most extensive measurement options.
Additional benefits of the Orion AquaMate 8100 UV-Visible Spectrophotometer include:
- Dual-beam optical geometry for more accurate measurements
- High-intensity XENON Lamp
- Flexible bandwidth
- Fast wavelength scanning
Dual-beam optics for more accurate measurements
The XENON flash lamp provides very intense light, allowing a beam splitter to extract and measure a small portion of light to an internal reference detector without a loss of performance in sample measurement. This provides
simultaneous measurement of the sample with real-time reference beam correction for each flash of the lamp.
The dual beam optical configuration ensures each measurement is as accurate as possible with reference beam correction on each data point, no drift over long
measurements and no peak shift with scan speed changes. The optical geometry offers enhanced data quality throughout the entire UV to near IR region of the
spectrum. The XENON flash lamp fires pulses of light only when taking a measurement
XENON flash lamp for increased lifespan
The XENON lamp in the Orion AquaMate 8100 UV-Visible Spectrophotometer provides excellent performance over the entire wavelength range of 190 to 1100 nm. It also provides intense light in the UV region of the spectrum adding sensitivity for life science, environmental and organic chemistry applications.
The XENON lamp typically provides three to five years of maintenance-free performance*, since it runs only when taking a measurement. This saves an average of $2,400 in maintenance costs** over five years compared with a
traditional light instrument. The XENON flash lamp requires no warm-up for instant
measurements. The lamp helps prevent damage to sensitive samples by flashing, versus continuous exposure to intense UV light and helps ensure sample temperature stability, since it does not change the compartment temperature.
Flexible nm bandwidth
The Orion AquaMate 8100 UV-Visible Spectrophotometer
balances regulatory compliance with sensitivity. A 1.8 nm spectral bandwidth provides optimal system resolution, permitting more light energy to reach the sample, thus resulting in lower detection limits and superior signal-tonoise performance.
Fast wavelength scanning
The Orion AquaMate 8100 UV-Visible Spectrophotometer is equipped with enhanced wavelength scanning technology that acquires high quality spectral data quickly. The instrument accelerates through wavelength scans at speeds up to 1600 nm/min. The exceptionally large photometric range allows accurate measurements of small absorbance changes even when using highly absorbing blank samples. Scan data can be analyzed to determine peak and valley wavelength. The scan data can also be
saved to the USB memory stick.
Product specifications and ordering information
Orion AquaMate UV-Visible
Spectrophotometer
Cat. No. 8100 | Orion AquaMate Visible
Spectrophotometer
Cat. No. 7100 | |
Optical Design | Dual beam | Dual beam |
Spectral Bandwidth | 2.0 nm | 5.0 nm |
Light Source (Typical Lifetime) | XENON flash lamp
(5 years typical) | Tungsten-halogen lamp
(1000 hours typical) |
Detector | Dual silicon photodiodes | Dual silicon photodiodes |
Wavelength | ||
Range | 190 to 1100 nm | 325 to 1100 nm |
Accuracy | 0.5 nm | 0.5 nm |
Repeatability | <±0.2 nm | <±0.2 nm |
Scanning Speed | Slow, medium and fast (up to 1600 nm/min) | Automatic— up to 1800 nm/min |
Data Resolution | 0.2 nm, 0.5 nm, 1 nm, 2 nm, 5 nm | 0.2 nm, 0.5 nm, 1 nm, 2 nm, 5 nm |
Photometric | ||
Measurement Modes | Absorbance, % transmittance, concentration | Absorbance, % transmittance, concentration |
Range | –2A to +3.5A; <1000 %T to 0 %T; 9999 C | –3A to +3.5A; >1000 %T to 0 %T; 9999 C |
Accuracy | ±0.002A at 0.5A, ±0.004A at 1.0A, ±0.008A at
2.0A | ±0.002A at 0.5A, ±0.004A at 1.0A, ±0.008A
at 2.0A |
Noise | ≤0.00020A at 0A at 260 and 500 nm
≤0.00030A at 1A at 260 and 500 nm
≤0.00040A at 2A at 260 and 500 nm | ≤0.00020A at 0A at 260 and 500 nm
≤0.00030A at 1A at 260 and 500 nm
≤0.00040A at 2A at 260 and 500 nm |
Drift | <0.0005 A/hr | <0.0010A/Hr |
Stray Light | < 1.0%T 198 nm (KCl) , <0.05%T at 220 nm
(NaI),<0.03%T at 340 nm (NaNO2) | <0.05%T at 340 nm and 400 nm |
Display | 7-inch color touchscreen, fixed, high definition,
800 × 1280 pixels | 7-inch color touchscreen, fixed, high
definition, 800 × 1280 pixels |
Keypad | Glove compatible touchscreen | Glove compatible touchscreen |
Connectivity | USB type A port for USB stick (front panel),Duplex USB type B port for computer (rear
panel),Print via USB, Etheret or Wi-Fi | USB type A port for USB stick (front panel),Duplex USB type B port for computer (rear
panel),Print via USB, Etheret or Wi-Fi |
Dimensions (LxWxH) | 5.5 × 38.5 × 19.5 cm | 5.5 × 38.5 × 19.5 cm |
Weight | 7.5 kg | 7.5 kg |
Power Requirements | External AC to DC converter. Voltage and
Frequency (Hz) selected automatically, 100–240
volts, 50–60 Hz | External AC to DC converter. Voltage and
Frequency (Hz) selected automatically, 100–240
volts, 50–60 Hz |