Humidity and Temperature Transmitter
- Vaisala - HMS110
- ±2%RH outdoor sensors for HVAC
- Integrated solar radiation shield
- Minimal maintenance
±2%RH outdoor sensors for HVAC
Vaisala HUMICAP Humidity and Temperature Transmitter Series HMS110 are ideal for cooling tower control and differential enthalpy control of economizers. The HMS110 directly outputs wet-bulb temperature, enthalpy and dew-point in addition to RH and temperature. These ±2% transmitters include an integrated radiation shield to reduce the influence of solar radiation on temperature and humidity measurements and to ensure measurement accuracy in outdoor conditions.
Key Benefits
Minimal maintenance
The sensor’s superior stability ensures long-lasting accuracy and minimal maintenance throughout the transmitter’s lifetime.
HMS110 transmitters are easy to install
They can be mounted directly on to a wall or pole without any extra accessories.
Integrated radiation shield
The integrated radiation shield allows unrivaled measurement performance, reducing the impact of the sunshine on temperature and humidity measurements and ensuring measurement accuracy in outdoor conditions.
HMS110 transmitters are equipped with the trusted HUMICAP 180R – a robust, general-purpose humidity sensor that functions well in high humidity. The sensor’s superior stability ensures long-lasting accuracy and minimal maintenance throughout the transmitter’s lifetime. If necessary, the transmitters can be field-calibrated using either the Vaisala HM70 Handheld Humidity and Temperature Meter, or a PC connection.
Two product models are available: HMS110 and HMS112.
Features
- Integrated solar radiation shield
- Calibration certificate included
- Proven HUMICAP® 180R sensor for long-lasting accuracy
- 3-point traceable calibration (certificate included)
- Current output (4...20 mA)
- On-site calibration with HM70 Hand-Held Meter or PC connection
- Ingress protection IP65
Model | Type | Output | IP Rating |
HMS110 | Outdoor, RH+T | 2-wire, current output | IP65 |
HMS112 | Outdoor, RH+T | 2-wire, current output | IP65 |
HMS110 is delivered with customer specific output settings, including calculated humidity parameters and special scaling of outputs.
Relative Humidity | |
Measurement range | 0 ... 100 %RH |
Stability in typical HVAC applications | Stability in typical HVAC applications |
Humidity sensor | Vaisala HUMICAP 180R |
Accuracy at temperature range | +10 … +30 °C (+50 … +86 °F) |
0 … 90 %RH | ±2 %RH |
90 … 100 %RH | ±3 %RH |
Accuracy at temperature range | =20 … +10 °C, +30 … +60 °C (-4 … +50 °F, +86 … +140 °F): |
0 … 90 %RH | ±3 %RH |
90 … 100 %RH | ±4 %RH |
Accuracy at temperature range | -40 … -20 °C (-40 … -4 °F): |
0 ... 100%RH | ±4 %RH |
Temperature | |
Measurement range | -40 … +60 °C (-40 … +140 °F) |
Accuracy at +20 °C (+68 °F) | ±0.2 °C (±0.36 °F) |
Temperature dependence | ±0.01 °C/°C |
Temperature sensor | Pt1000 RTD Class F0.1 IEC 60751 |
Calculated Parameters | |
Factory calibration uncertainty | at 20 °C
(+68 °F)
±1.5 %RH/±0.2 °C |
Measurement range for dew point
temperature and wet bulb temperature | -40 … +60 °C (-40 … +140 °F) |
Measurement range for enthalpy | -40 … 460 kJ/kg (-10 … +190 BTU/lb) |
Accuracy of the calculated parameters should be calculated at the actual condition based on the RH and temperature specification. | |
Accuracy at 20 °C (68 °F) and 80 %RH: | |
Dew point | ±0.7 °C (1.2 °F) |
Wet bulb temperature | ±0.5 °C (0.9 °F) |
Enthalpy | ±1.6 kJ/kg (0.7 BTU/lb) |
Operating temperature | -40 … +60 °C (-40 … +140 °F) |
Operating humidity | 0 … 100 %RH |
Maximum wind/flow speed | 30 m/s (67 mph) |
Storage temperature | -40 … +60 °C (-40 … +140 °F) |
EMC compliance | EN61326-1, Industrial Environment |
Analog outputs | 4 … 20 mA, loop powered |
Loop resistance | 0 … 600 Ω |
Supply voltage | 20 … 28VDC at 600 Ω load 10 … 28VDC at 0 Ω load |
Data input for RDP100 Remote Panel
Display | RS-485
Vaisala proprietary protocol |
Max. wire size | 1.5 mm2
(AWG 16) |
Standard housing color | White (RAL9003) |
Housing material | PC + 10 %GF (UL-V0 approved) |
Remote Panel Display | RDP100 |
Conduit fitting + O-ring (M16 × 1.5 /
NPT1/2 Inch) | 210675SP |
Conduit fitting + O-ring (M16 × 1.5 /
PG9, RE-MS) | 210674SP |
Fastening set HMS110 | 237805 |
Membrane Filter | ASM210856SP |
Terminal Block, Blue | 236620SP |
USB cable for PC connection | 219690 |
Connection cable for HM70 hand-held
meter | 219980SP |
HUMICAP 180R sensor | HUMICAP180R |
Can we help you?