Smart Monitoring Technology
- Water resources management
- Mining
- Surface water
- Remediation
Van Essen Instruments
offers a complete portfolio with regards to technology as well as advice in the field of groundwater monitoring networks. Reliable and accurate sensors are being combined with the latest developments in the field of wireless communication and data
visualization. Van Essen Instruments not only offers high-quality groundwater data but also solutions to manage a groundwater monitoring network more effective and efficient.
Diver-Suite
Diver-Suite from Van Essen Instruments provides a robust line of Diver dataloggers for groundwater and environmental professionals. The Diver dataloggers accurately measure and record fluctuations in groundwater levels, temperature and conductivity.
Suitable for Any Environment
From the technologically advanced TD-Diver to the corrosion resistant CTD-Diver, Diver dataloggers are hermetically sealed to external influences. Electrical and/or environmental effects cannot affect the measurement results.
With an extended battery life up to 10 years, this translates to long-term uninterrupted service. Divers can be used from 300 meters below to 5,000 meters above sea level without the need to reprogram the datalogger.
All Divers operate from -20 to 80 °C.
Accurate Measurements
Divers monitor groundwater pressure with a typical accuracy of ±0.05% full scale range from 0 to 50 °C. The CTD-Diver is equipped with a four-electrode sensor for recording conductivity with an accuracy of ±1% of reading
TD-Diver
Superior Long-term Performance
The TD-Diver is based on an ingenious and proven
concept and is acknowledged as the most reliable
instrument for the autonomous measuring and
recording of groundwater level and temperature.
Its internal working memory of 72,000
measurements per parameter provides sufficient
capacity to perform one measurement every
15 minutes for over 2 years.
For each measurement, the Diver registers the date
and time, groundwater level, and temperature.
- Long-term groundwater monitoring
- Watershed and recharge area monitoring
- Storm water discharge
Baro-Diver
Reference of Choice
The Baro-Diver ensures that you accurately capture changes in atmospheric pressure. Conveniently priced and easy to deploy, one Baro-Diver covers a radius of up to 15 km, depending on the topography.
The Baro-Diver can also be used for measuring shallow water levels up to approximately 0.9 meter. The Baro-Diver has an internal working memory capable of storing 72,000 measurements per parameter.
For each measurement, the Baro-Diver simultaneously registers barometric pressure, air temperature, date and time.
- Atmospheric pressure
- Wetlands monitoring
- Flood management
Micro-Diver
Compact Size
Measuring only 88 mm in length and 18 mm in diameter, the Micro-Diver is the smallest Diver capable of accurately recording groundwater levels and temperature. The Micro-Diver is specifically designed for monitoring wells or drive-points too small to
accommodate larger dataloggers. In addition to its compact size, the MicroDiver’s memory capacity can store up to 48,000 measurements per parameter - almost one measurement every ten minutes for an entire year.
- Engineering and construction
- Shallow water monitoring
- Aquifer characterization
Cera-Diver
Corrosion Proof
Monitoring groundwater under potentially corrosive conditions, such as brackish water and seawater, requires a robust and durable datalogger. The ceramic-shelled Cera-Diver is designed specifically for such environments. This highly reliable and compact Diver measures groundwater levels with a typical accuracy of ±0.05% full scale. The Cera-Diver is equipped with a memory for 48,000 measurements per parameter.
- Estuary monitoring
- Heap leach
- Underground plume monitoring
CTD-Diver
3 Parameters in 1 Housing
Where there is a need to monitor groundwater levels and saltwater intrusion, injected wastewater, or contamination from chemical discharges and landfill sites, the CTD-Diver with its rugged, corrosion proof
ceramic housing, is the instrument of choice.The CTD-Diver is equipped with a four-electrode conductivity sensor that measures electrical conductivity from 0 to 120 mS/cm. There are two options for measuring conductivity: true or specific conductivity at 25 °C. Additionally, pressure and temperature are measured and recorded.
- Mine tailings
- Pollution monitoring
- Water quality monitoring
Diver Data Management Software
User-friendly applications for your Desktop or Handheld PC
Diver-Office Premium
Diver-Office Premium* software provides users with a full range of tools for management of well location details, displaying borehole lithology and well construction data, plotting time-varying Diver data (groundwater elevation, temperature, conductivity),and validating data quality in a seamlessly integrated groundwater software package.
- Diver Data Management - Program Diver dataloggers, start/stop Divers and download Diver data to a shared SQL database.
- Monitoring Well Data Management - Create, modify and display X, Y location data, borehole lithology and well construction details.
- Shared Database - Securely share Diver data over a network and collaborate with all team members in your groundwater monitoring projects.
- Expanded Data Options - Capture a full range of environmental variables affecting groundwater recharge including precipitation, evaporation, and discharge data.
- QA/QC and Statistics - Apply essential QA/QC checks to raw data, identify and correct data anomalies, and gain confidence in your data assessments.
- Report Automation - Effectively communicate and present monitoring data, location details, well construction data and lithology in detailed reports and customized time series plots.
- Data Flexibility - Export well profiles to image files, export time-series data to ExcelTM, import location data from ExcelTM/AccessTM.
Create detailed time-series plots
Report on well construction and lithology
Diver-Pocket
Built for your Handheld PC or PDA, the Diver-Pocket* software reads data stored in Diver dataloggers, displays time-series plots, and exports data to various formats.
Diver-Pocket Premium
The Diver-Pocket Premium* software extends the features of Diver-Pocket, with the added capability to program Divers, including the measurement method, frequency, and the start date/time.
Diver-Office
Use the Diver-Office* desktop application to calibrate, read, and program all Divers in the Diver-Suite. Download measurements onto your PC, view time series data in a plot or tabular form, and export data to a spreadsheet or groundwater modeling program.
* Typical accuracy 1 Only available with CTD-Diver. 2 Baro-Diver: -10°C to 50°C
Dimensions (LxD) | 110 mm × 22 mm | |||
Memory | 72,000 measurements with backup; continuous and fixed length memory | |||
Wetted parts | Housing | Stainless steel (316L) | ||
O-Rings | Viton ® | |||
Pressure sensor | piezoresistive ceramic | |||
Cap / Nose cone | Nylon PA6 30% glass fiber / ABS | |||
Battery life | up to 10 years (dependent on usage) | |||
Sample interval | 0.5 second to 99 hours | |||
Sample methods | fixed | |||
Mass | 104 grams | |||
Temperature | ||||
Range | -20 to 80 °C | |||
Calibrated | 0 to 50 °C | |||
Accuracy* | ±0.1°C | |||
Resolution | 0.01°C | |||
Pressure | ||||
Part number | DI 801 | DI 802 | DI 805 | DI 810 |
Range | 10 | 20 | 50 | 100 mH2O |
Accuracy* | ±0.5 | ±1.0 | ±2.5 | ±5.0 cmH2O |
Resolution | 0.6 | 0.09 | 0.19 | 0.36 cmH2O |
* Typical accuracy
Dimensions (LxD) | 88 mm × 18 mm | |||
Memory | 48,000 measurements with backup; continuous and fixed length memory | |||
Wetted parts | Housing | Stainless steel (316L) | ||
O-Rings | Viton ® | |||
Pressure sensor | piezoresistive ceramic | |||
Cap / Nose cone | Nylon PA6 30% glass fiber / ABS | |||
Battery life | up to 10 years (dependent on usage) | |||
Sample interval | 0.5 second to 99 hours | |||
Sample methods | fixed, event dependent, averaging, and pumping test | |||
Mass | 45 grams | |||
Temperature | ||||
Range / compensated | -20 to 80 °C | |||
Calibrated | 0 to 50 °C | |||
Accuracy | ±0.1°C | |||
Resolution | 0.01°C | |||
Pressure | ||||
Part number | DI 601 | DI 602 | DI 605 | DI 610 |
Range | 10 | 20 | 50 | 100 mH2O |
Accuracy* | ±1.0 | ±2.0 | ±5.0 | ±10.0 cmH2O |
Resolution | 0.06 | 0.09 | 0.19 | 0.36 cmH2O |
* Typical accuracy
Dimensions (LxD) | 90 mm × 90 mm | |||
Memory | 48,000 measurements | |||
Wetted parts | Housing | Ceramic (ZrO2) | ||
O-Rings | Viton ® | |||
Pressure sensor | piezoresistive ceramic | |||
Cap / Nose cone | Nylon PA6 30% glass fiber / ABS | |||
Battery life | up to 10 years (dependent on usage) | |||
Sample interval | 0.5 second to 99 hours | |||
Sample methods | fixed, event dependent, averaging, and pumping test | |||
Mass | 50 grams | |||
Temperature | ||||
Calibrated | -20 to 80 °C | |||
Range | 0 to 50 °C | |||
Accuracy* | ±0.1°C | |||
Resolution | 0.01°C | |||
Pressure | ||||
Part number | DI 701 | DI 702 | DI 705 | DI 710 |
Range | 10 | 20 | 50 | 100 mH2O |
Accuracy* | ±0.5 | ±1.0 | ±2.5 | ±5.0 cmH2O |
Resolution | 0.06 | 0.09 | 0.19 | 0.36 cmH2O |
* Typical accuracy
Dimensions (LxD) | 135 mm × 22 mm | ||
Memory | 48,000 measurements with backup; continuous and fixed length memory | ||
Wetted parts | Housing | Ceramic (ZrO2) | |
Conductivity sensor housing | Ceramic (ZrO2) | ||
Conductivity sensor | Platinum electrodes on ceramic (Al2O3) carrier | ||
O-Rings | Viton ® | ||
Pressure sensor | piezoresistive ceramic | ||
Cap / Nose cone | Nylon PA6 30% glass fiber / ABS | ||
Battery life | up to 10 years (dependent on usage) | ||
Sample interval | 1 second to 99 hours | ||
Sample methods | fixed, event dependent, averaging, and pumping test | ||
Mass | 95 grams | ||
Temperature | |||
Range | 20 to 80 °C | ||
Calibrated | 0 to 50 °C | ||
Accuracy* | ±0.1°C | ||
Resolution | 0.01°C | ||
Conductivity | |||
Range 1 | 0 to 120 mS/cm | ||
Range 2 | 0 to 30 mS/cm | ||
Accuracy* | ± 1 % of reading | ||
Resolution | 0.1 % of reading | ||
Pressure | |||
Part number | DI 271 | DI 272 | DI 273 |
Range | 10 | 50 | 100 mH2O |
Accuracy* | ±0.5 | ±2.5 | ±5.0 cmH2O |
Resolution | 0.06 | 0.19 | 0.36 cmH2O |
* Typical
Dimensions (LxD) | 110 mm × 22 mm | ||
Memory | 72,000 measurements with backup; continuous and fixed length memory | ||
Wetted parts | Housing | Stainless steel (316L) | |
O-Rings | Viton ® | ||
Pressure sensor | piezoresistive ceramic | ||
Cap / Nose cone | Nylon PA6 30% glass fiber / ABS | ||
Battery life | up to 10 years (dependent on usage) | ||
Sample interval | 0.5 second to 99 hours | ||
Sample methods | fixed | ||
Mass | 104 grams | ||
Temperature | |||
Range | -20 to 80 °C | ||
Calibrated | -10 to 50 °C | ||
Accuracy* | ±0.1°C | ||
Resolution | 0.01°C | ||
Pressure | |||
Part number | DI 800 | ||
Range | 1.5 mH2O | ||
Accuracy* | ±0.5 cmH2O | ||
Resolution | 0.03 cmH2O |