CO2 incubators with hot air sterilization and heat sterilizable CO2 sensor

  • Binder - CB 56, CB 170, CB 260

View Quote

Fast response from our specialists

Why buy from Geneq? - find out more


Do you have a question?

CO2 incubators with hot air sterilization and heat sterilizable CO2 sensor

  • Safe – cell cultures receive maximum protection against contamination
  • Reliable – constant well-being conditions for the cells
  • Smart – simple routine cleaning and convenient operation
  • Economical – efficient operation without consumables

The powerful and versatile CB CO₂ incubator is suitable for cell-based assays in drug and medical research. This BINDER incubator is even suitable for complex cultivation experiments or individual environments with hypoxic conditions thanks to its comprehensive assortment of options and accessories.

Characteristics

  • Optimized double-pan humidification system with condensation protection
  • Tried-and-tested anti-contamination concept with 180°C hot air sterilization
  • Hot-air sterilizable CO₂ sensor with single-beam infrared technology
  • Seamless inner chamber made of stainless steel with flanges as shelf support system
  • Fanless interior with Venturi CO₂ gas mixing nozzle
  • Intuitive touchscreen controller
  • Internal data recording, can be read out in open format via USB interface
  • Fault diagnosis system with visual and acoustic alarm
  • Interfaces: Ethernet, USB, zero-voltage alarm contact
  • Fail-safe CO₂ system for protecting the pH of cell cultures

Models / Dimensions incl. fittings and connections [inch]

CB 56

CB 170

CB 260

ModelsCB 56CB 170CB 260
Measures
Interior volume [L]53170267
Net weight of the unit (empty) [kg]5398125
Permitted load [kg]303040
Load per rack [kg]101010
Wall clearance back [mm]100100100
Wall clearance sidewise [mm]505050
Internal Dimensions
Width [mm]400560620
Height [mm]400600750
Depth [mm]330505575
Housing dimensions not incl. fittings and connections
Width net [mm]528680740
Height net [mm]6748701020
Depth net [mm]545715785
Performance Data Temperature
Temperature range +4-6 °C above ambient temperature to [°C]6060-
Temperature range +5-6 °C above ambient temperature to [°C]--60
Temperature variation at 37 °C [± K]0.30.30.4
Temperature fluctuation at 37 °C [± K]0.10.10.1
Recovery time after 30 seconds door open at 37 °C [min]566
Performance Data Climate
Humidity range [% RH]90…9590…9590…95
CO₂-Data
CO₂ range [Vol.-% CO₂]0…200…200…20
CO₂ measurementIRIRIR
Electrical data
Nominal power (version 120 V) [kW]0.81.41.5
Nominal power (version 230 V) [kW]0.81.41.5
Fixtures
Number of shelves (std./max.)2/33/63/8