Provides Feature-Rich Operator Safety for General Applications. Meets or Exceeds OSHA, ANSI and other International Standards.
The Purair Basic ductless fume hoods are a series of high efficiency products designed to protect the user and the environment from hazardous vapors generated on the work surface. At the heart of the Purair fume hood product line is the innovative Air Science Multiplex Filtration Technology that creates a safe work environment over the widest range of applications in the industry.
Ductless Technology - The Eco-friendly Choice
Advanced carbon filtration technology offers a safe, high performance alternative to conventional ducted fume hoods for a broad range of applications.
- Environmental Benefits - Air Science® ductless fume hoods isolate and trap chemical vapors to prevent ecological impact through release into the environment.
- Versatile - Each filtration system is selected for its specific application. The Multiplex Filter broadens the range of applications. Carbon filters are available in more than 14 configurations for use with vapors or organic solvents, acids, mercury and formaldehyde. HEPA/ULPA fi lters can add to biological safety.
- Easy to Install - The ductless fume hood is self-contained and does not require venting to the outside. Many units are portable and may be moved from one location to the next with minimal downtime and without filter changes. Set-up, operation and filter maintenance are straightforward.
- Energy Efficient - Because filtered air is returned to the room, no demands are required of the facility HVAC capacity for make-up air.
- Cost Effective- Facility ductwork, HVAC and construction costs are eliminated.
- Safe to Use - Cabinet airflow and face velocity protect users from incidental exposures to fumes.
- Self testing (selected models) - Electronic air-flow monitoring assures continuous safety. An electronic gas sensor monitors carbon filter performance.
Applications
- Compounding
- Enclosing balances, microscopes, and robotic equipment
- Forensics
- Histology
- Educational
- Microscopy
- Mobile and classroom demonstrations
- Pharmaceutical
- Powder fingerprinting
- Powder weighing
- Sample prep work
- Soldering
- Solvent cleaning and welding
- Veterinary and dental work
Products features
A. Filter I.D. Window: A strategically placed front cover window shows the installed filter part number and installation date for convenience and to encourage timely filter replacement.
B. Air Velometer: (Optional) An analog air velocity meter in the field of vision of the user.
C. Hinged Front Sash: When closed, the cabinet sash protects the contents from inadvertent external contact, and better isolates the air within. The sash is easy to open and close.
D. Control Panel: Electronic controls and displays include switches for the blower and low airflow alarm.
E. Steel Support Frame: The chemical resistant epoxy coated steel frame adds mechanical strength. Optional all polypropylene construction is available if desired; see accessories. The pre-filter can be changed while the unit is operating to prevent operator exposure to chemical vapors.
F. Electrostatic Pre-Filter: The 99.5% effective electrostatic pre-filter is accessible from inside the chamber to contain the release of any particulates that it traps.
G. Pass Through Ports: Electrical cords and cables are safely routed into the cabinet through ports on the back and side walls.
H. Color: The cabinet is white with blue trim; side and back panels are clear.
I. Airflow Alarm: A continuous air velocity monitoring system alerts the operator upon unacceptable values.
J. Manual Speed Controller: The operator may set the centrifugal fan motor speed as desired.
K. Stand: Optional mobile cart with locking casters.
L. Work Surface: The internal work surface can be fitted with an optional polypropylene tray; see Accessories.
M. Filter Door Key: Filter access keys prevent unauthorized removal or accidental exposure to dirty filters.
Others Features
- 360 Degree Visibility: Clear back and side panels allow ambient illumination into the chamber and provide users with an unobstructed view of its contents.
- Standards Compliant: Performance specifications and construction meet or exceed OSHA, ANSI and relevant international standards to assure operator safety.
- Construction: All models are available in either metal or polypropylene construction. See selection chart for specifications and dimensions. Specify metal or polypropylene when ordering. Available in 110V, 60Hz or 220V, 50Hz models.
Models
STANDARDS & COMPLIANCE | |
Quality Management Systems | ISO 9001 |
Chemical Fume Containment | ANSI/ASHRAE 110 1995 |
Carbon Filter Efficiency | BS 7989-2001 AFNOR NFX 15-211 |
Biological Safety Filter Efficiency HEPA and ULPA | IEST-RP-CC-0034.2 IEST-RP-CC007.1 IEST-RP-CC001-4 EN 1822 |
Electrical Safety | UL-C-61010-1 CE Mark ROHS Exempt under EEE Category 9 |
Product Design | ANSI Z 9.5-2003 ANSI Z 9.7-1998 |
OSHA, Occupational Safety and Health Administration | OSHA Standard -29 CRF, Safety and Health Regulations for General Industry, 1910.1450: Occupational exposure to hazardous chemicals in laboratories. Part B, definition, laboratory type hood. All Air Science products meet this definition. |
Environment | ISO 14001 Energy Star Partner |
Filter Summary
Formula | Description |
GP Plus! | The most widely used filter in the range, primarily for solvent, organic, and alcohol removal. |
ACI Plus! | Neutralizes volatile inorganic acid vapors. |
ACR | Iodine and methyl iodide vapors. It is frequently used for iodination reactions with low level radioactive iodine. |
ACM | Mercury vapor. |
AMM | Removes vapors from dilute ammonia solutions and to remove low molecular weight amines. |
SUL | Designed to remove hydrogen sulfide and low molecular weight mercaptans. |
CYN | Removal of hydrogen cyanide. Many cyanide compounds will evolve HCN gas if acidified, so this filter is normally specified if working with any cyanide compound. |
FOR | Designed to oxidize formaldehyde and glutaraldehyde fumes. It is widely used in hospital pathology laboratories. |
ETH | Diethyl ether is adsorbed on activated carbon, but because of its low boiling point, local heat adsorption can reduce the capacity of the filter. Special impregnation allows a chemical reaction which increases the filter capacity. |
HEPA/UPLA | Powders and particulates. |
MODEL | DIMENSIONS | WEIGHT (lbs/Kg) | |||
Internal Height | External (W x D x H) | Shipping (W x D x H) | Net | Ship | |
Standard Models | |||||
P5-24 | 19" 484 mm | 24" x 27" x 31" 610 x 676 x 781 mm | 40" x 40" x 40" 1016 x 1016 x 1016 mm | 68 / 31 | 125 / 57 |
P5-36 | 19" 484 mm | 36" x 27" x 31" 914 x 676 x 781 mm | 40" x 40" x 40" 1016 x 1016 x 1016 mm | 95 / 43 | 152 / 69 |
P5-48 | 19" 484 mm | 48" x 27" x 31" 1219 x 676 x 781 mm | 45" x 55" x 40" 1143 x 1397 x 1016 mm | 133 / 60 | 190 / 86 |
Straight Models (Reduced Depth) | |||||
P5-24S | 19" 484 mm | 24" x 24" x 31" 610 x 610 x 781 mm | 40" x 40" x 40" 1016 x 1016 x 1016 mm | 65 / 29 | 110 / 50 |
P5-36S | 19" 484 mm | 36" x 24" x 31" 914 x 610 x 781 mm | 40" x 40" x 40" 1016 x 1016 x 1016 mm | 92 / 42 | 142 / 64 |
P5-48S | 19" 484 mm | 48" x 24" x 31" 1219 x 610 x 781 mm | 45" x 55" x 40" 1143 x 1397 x 1016 mm | 130 / 59 | 187 / 85 |
Extra Tall Models | |||||
P5-24-XT | 23.6" 600 mm | 24" x 27" x 35" 610 x 676 x 889 mm | 40" x 40" x 40" 1016 x 1016 x 1016 mm | 72 / 33 | 129 / 59 |
P5-36-XT | 23.6" 600 mm | 36" x 27" x 35" 914 x 676 x 889 mm | 40" x 40" x 40" 1016 x 1016 x 1016 mm | 99 / 45 | 157 / 71 |
P5-48-XT | 23.6" 600 mm | 48" x 27" x 35" 1219 x 676 x 889 mm | 45" x 55" x 40" 1143 x 1397 x 1016 mm | 138 / 63 | 195 / 88 |
Extra Tall Straight Models (Reduced Depth) | |||||
P5-24-XTS | 23.6" 600 mm | 24" x 24" x 35" 610 x 610 x 889 mm | 40" x 40" x 40" 1016 x 1016 x 1016 mm | 72 / 33 | 129 / 59 |
P5-36-XTS | 23.6" 600 mm | 36" x 24" x 35" 914 x 610 x 889 mm | 40" x 40" x 40" 1016 x 1016 x 1016 mm | 99 / 45 | 157 / 71 |
P5-48-XTS | 23.6" 600 mm | 48" x 24" x 35" 1219 x 610 x 889 mm | 45" x 55" x 40" 1143 x 1397 x 1016 mm | 138 / 63 | 195 / 88 |
Purair Model | P5-24 P5-24S P5-24-XT P5-24-XTS | P5-36 P5-36S P5-36-XT P5-36-XTS | P5-48 P5-48S P5-48-XT P5-48-XTS |
Airflow CFM | 135.9 | 206 | 281.25 |
Face Velocity FPM | 100 | 100 | 100 |
Noise, dBA, 1 meter | < 50 | < 50 | < 53 |
Lighting | Compact fluorescent lamp. | ||
Construction | White epoxy coated steel frame and head unit. Clear sides and back panel. | ||
Blower | ebmpapst™ centrifugal fan. | ||
Electrical | 120V, 60Hz or 220V, 50Hz voltages available. Specify when ordering. Other voltage options available. | ||
Electrical Switches | Main On/Off | ||
Monitoring | Low airflow alarm, standard. | ||
Filter Specifications | |||
Pre-Filter | Electrostatic, 1 lb / .45 kg (nominal) | ||
Main* | (1) 11 lbs / 5 kg | (1) 11 lbs / 5 kg | (2) 11 lbs / 5 kg |
* Single stack; double stack doubles weight of all (i.e. 22, 22, 44).