CDR FoodLab Touch
- 222003Z01
Voir la soumission
Réponse rapide par nos spécialistes
Avantages de faire affaire avec Geneq - en savoir plus
Analysis System for Fats and Oils
Fats and Oils | |
Acidity (FFA) | Peroxide value (PV) |
p-Anisidine value (AnV) | Iodine value (only in palm oil) |
Polyphenols (OSI) (only in olive oil) | Soaps |
Strengths
CDR FoodLab Touch is composed of a thermostated analyzer based on photometric technology that uses LEDs instead of usual tungsten lamps.This, with specific software, innovative analytical procedure and dedicated reagents, makes the CDR FoodLab Touch a unique and advanced analysis system. Reagents are pre-vialed, in package of 10 tests, 1 year shelf life, developed and produced by the research laboratories of CDR.
Reduced Testing Time
Now it is possible to perform an analysis quickly and easily without relying on a dedicated external laboratories.It is possible to analyze 16 samples at the same time and constantly monitor the production process, obtaining exact and accurate answers in just a few minutes.The multitasking mode allows to manage the determinations of several analytical parameters at the same time. It allows the system to process one analysis and to start another one at the same time, with the possibility to go back to the first one at any moment.
Reliable
This measuring system owes its sensitivity, accuracy and reliability to the photometric technology based on LED luminous sources. The results of the analysis are correlated with the reference methods
Analysis System For Fats And Oils
Free Fatty Acids (FFA),PeroxideValue (PV),p-AnisidineValue (AnV). You can determine them in 5 minutes, in a simple way with pre-vialed and low environmental impact reagents, in respect of operator's safety, abandoning the use of toxic solvents, extractor hoods, complex analytical instruments and complicated methods. With CDR FoodLab Touch you can have all of this directly on line production.
Tests | Measuring range | Resolution | Repeatability |
Free Fatty Acids | 0,01 - 1,10 % oleic acid | 0,01% | 0,02% |
0,90 - 3,50 % oleic acid | 0,1% | 0,1% | |
1 - 26,03 % oleic acid | 0,1% | 0,5% | |
Peroxide Value | 0,01 - 5,5 meqO /Kg | 0,01 meqO /Kg | 0,1 meqO /Kg |
0,5 - 50 meqO /Kg | 0,01 meqO /Kg | 0,3 meqO /Kg | |
4 - 550 meqO /Kg | 0,1 meqO /Kg | 3 meqO /Kg | |
p-Anisidine | 0,5 - 100 AnV | 0,1 AnV | 0,5 AnV |
Iodine Value | 2 - 100 g/100g | 1 g/100g | 2 g/100g |
Soap | 1 - 3000 ppm sodium oleate | 1 ppm | 5 ppm |
Polyphenols | 10-900 mg/kg gallic acid | 1 mg/kg gallic acid | 5 mg/kg gallic acid |
Easy To Use | |
The system is designed to be used by anyone, without the support of skilled staff. The analysis methods are easier than the traditional ones and can be performed in few steps : | |
1. Adding the sample volume to the previaled reagent. | ![]() |
2. Following the displayed instructions and if there is ever a doubt, the HELP function will lead you through the process. | ![]() |
3. Results are automatically calculated, displayed and printed. | ![]() |
Reagents are pre-vialed, in package of 10 tests, 1 year shelf life, developed and produced by the research laboratories of CDR.
Fast, Simple, Reliable
Each test is performed dispensing in the cuvette containing the buffer a determined amount of the sample. Thanks to the reagents created on purpose, it is generated a colorimetric reaction. The result of the test is printed immediately after the elaboration of the photometric reading, in its unit of measure.
CDR FoodLab systems | ||
Code | Description | |
222003Z01 | CDR FoodLab Touch, designed for different kinds of fats and oils, is configured with the complete analysis panel (complete configuration). It is able to analyze 16 samples at the same time, endowed with 5,7” LCD touchscreen, printer, incubation cells, ethernet (LAN) connection, USB for PC connection, USB for the trasfer of the analyses' data. | ![]() |
242001Z01 | CDR FoodLab Junior, designed for different kinds of fats and oils, can be configured with some analysis of your choice (tailored configuration). It is able to anlayze 3 samples at the same time, endowed with 4,3” LCD touchscreen, USB for PC connection, bluetooth 2.1 | ![]() |
Product Description | Our Code | Your Code | MU | Q.TY |
Additional Configuration for p-Anisidine test | NR | 1 | ||
Additional Configuration for Sopas test NR 1 | NR | 1 | ||
Additional Configuration for Iodine Value test (only for NR 1 700,00 30,00 490,00 Palm oil) | NR | 1 | ||
Additional Configuration for Polyphenols (only for NR 1 700,00 30,00 490,00 olive oil) | NR | 1 | ||
Reagents Kit | ||||
Acidity (Ffa) Kit On Oils/Fats 100 Tests | *300125 | NR | 1 | |
Acidity (Ffa) Kit On Oils/Fats 10 Tests | *300128 | NR | 1 | |
Peroxydes (Pv) Kit On Oils/Fats 100 Tests | *300150 | NR | 1 | |
Peroxides (Pv) Kit On Oils/Fats 20 Tests | *300159 | NR | 1 | |
P-Anisidine (Anv) Kit On Oils/Fats 100 Tests | *300500 | NR | 1 | |
P-Anisidine (Anv) Kit On Oils/Fats 10 Tests | *300503 | NR | 1 | |
Polyphenols Kit On Olive Oil 100 Tests | *300475 | NR | 1 | |
Polyphenols Kit On Olive Oil 10 Tests | *300478 | NR | 1 | |
Soaps Kit On Oils/Fats 100 Tests | *300175 | NR | 1 | |
Soaps Kit On Oils/Fats 20 Tests | *300183 | NR | 1 | |
Iodine Value (Iv) Kit On Palm Oil 100 Tests | *300560 | NR | 1 | |
Iodine Value (Iv) Kit On Palm Oil 10 Tests | *300561 | NR | 1 | |
Dilution Kit 100 Tests | *300129 | NR | 1 | |
4x25 mL bottles - 100 empty cuvettes - 100 caps Per analisi di acidità > 25% e perossidi fino a 550 meqO2/Kg |