Wireless temperature,humidity and CO2 logger
- TandD - RTR-576
- Channels: CO2 Concentration, Temperature, Humidity
- Range CO2: 0 to 9999ppm
- Temperature: 0 to 55°C
- Humidity: 10 to 95%RH
- Comm Interfaces: USB, Serial, Short Range Wireless
The RTR-500/RTR500B series allows you to mix and match an array of wireless radio communication loggers with various Base Units or Data Collectors to meet your needs.
Logged data can be automatically sent via network or mobile communication to be saved in cloud storage or to a specified location.
The RTR-576 is a three-channel data logger designed to measure and record CO2 concentration, temperature and humidity.
External devices such as buzzers and lights can also be connected to the contact output terminal to provide instant on-site notification, signaling when ventilation may be needed.
RTR-576 loggers have a wireless radio communication range with compatible base units of up to 150m (500ft).
Data can be transmitted from a logger to a base unit and then automatically uploaded to cloud storage or saved to a specified location. Data can also be checked on your PC screen or on site with one of our compatible data collectors.
RTR-576 is useful for measuring and managing CO2 in rooms and buildings from both near and far.
RTR-576 | ||
Temperature-Humidity Sensor | ||
Measurement Channels | Temperature 1ch | Humidity 1ch |
Sensor | THA-3001 | |
Thermistor | Polymer Resistance | |
Measurement Units | °C, °F | %RH |
Measurement Range (*1) | 0 to 55 °C | 10 to 95%RH |
Accuracy |
±0.5 °C | 5 %RH at 25 °C, 50 %RH |
Measurement Resolution | 0.1 °C | 1 %RH |
Responsiveness | Response Time (90%): Approx. 7 min. | |
CO2 Sensor (Internal) | ||
Measurement Channels | CO2 Concentration 1ch | |
Sensor | NDIR | |
Measurement Units | ppm | |
Measurement Range | 0 to 9,999 ppm | |
Accuracy | ±(50 ppm + 5% of reading) at 5,000 ppm or less (*3) | |
Measurement Resolution | Minimum of 1 ppm | |
Responsiveness | Response Time (90%): Approx. 1 min. |
Logging Capacity | 8,000 data sets (One data set consists of readings for all channels in that type of unit.) |
Recording Interval | Select from 15 choices: 1, 2, 5, 10, 15, 20, 30 sec. or 1, 2, 5, 10, 15, 20, 30, 60 min. |
Recording Mode (*4) | Endless (Overwrite oldest data when capacity is full) or One Time (Stop recording when capacity is full) |
LCD Display Items | Measurements, Recording Status, Recording Mode, Battery Level, etc. Measurements: CO2 concentration, Temperature or Humidity (fixed or alternating display) |
Communication Interfaces | Short Range Wireless Communication <For US> Frequency Range: 902 to 928MHz RF Power: 7mW Transmission Range: About 150 meters (500 ft) if unobstructed and direct <For EU> Frequency Range: 869.7 to 870MHz RF Power: 5mW Transmission Range: About 150 meters if unobstructed and direct USB 2.0 (Mini-B connector) Serial Communication (*5) |
External Alarm Terminal (*6) | Output Terminal: Open Drain Output (Voltage when OFF: DC less than 30V / Current when ON: less than 0.1A / Resistance when ON: about 15 ) |
Power | AC Adaptor AD-06A1 or AD-06C1, AA Alkaline Battery LR6 x 4 |
Battery Life (*7) | Approx. 2 days (batteries only without AC adaptor) |
Dimensions | H 96 mm x W 66 mm x D 46 mm (excluding protrusions and sensor) Antenna Length: 60 mm |
Weight | Approx. 125 g |
Operating Environment | Temperature: 0 to 45°C Humidity: 90 %RH or less (no condensation) |
Accessories | AA Alkaline Battery LR6 x 4, AC Adaptor AD-06A1 or AD-06C1, USB Mini-B Cable US-15C, Temperature-Humidity Sen- sor THA-3001 or SHA-3151, Manual (Warranty Included) |
Compatible Base Units | RTR500BC, RTR500BW, RTR500BM RTR-500, RTR-500NW/500AW, RTR-500DC, RTR-500MBS-A |
*1: Make sure to use the data logger within the operating environment as listed in the specifications.
*2: When continually used in environments with temperatures above 60°C, accuracy of humidity measurements will decrease over time. Also, humidity cannot be measured at temperatures below -20°C.
*3: Stated value is the measurement accuracy of the CO2 sensor when Auto Calibration is operating properly. A change in atmospheric pressure directly influ- ences the reading of CO2, which can cause measurement errors; a decrease in pressure by 10hPa results in a relative decrease in CO2 by 1.6%. In such a case, we recommend carrying out the “Atmospheric Pressure Correction” function found in the software for the Base Unit.
*4: Only “Endless” is available when using the RTR500BW, RTR500BM, RTR-500NW/AW or RTR-500MBS-A as a Base Unit.
*5: For communication with the Data Collector RTR-500DC (Note: Optional serial communication cable TR-6C10 is required.)
*6: In order to use the external alarm terminal, please purchase the optional alarm connection cable (AC0101).
*7: The listed battery life is based on the following usage conditions: Recording at 10 second (or longer) intervals, Current Readings Transmission every 10 minutes, and Recorded Data Transmission once a day. Battery life also varies depending on ambient temperature, radio environment, frequency of com- munication, etc.
The specifications listed above are subject to change without notice.
Can we help you?
min 10 ch